My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-07-13_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2016-07-13_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2020 11:22:05 PM
Creation date
7/13/2016 1:47:02 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
Hydrology
Doc Date
7/13/2016
Doc Name
Water Monitoring - Groundwater
From
Golder Associates
To
DRMS
Annual Report Year
2016
Report Quarter_Month
2
Email Name
ECS
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. • ® • ' ® ® • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 A - • <br /> Golder Associates ACZ Project ID: L30739 <br /> METHOD�ACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L30739-02 WG404177 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L30739-04 WG404177 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L30739-06 WG404177 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L30739-06 WG404014 pH SM4500H+B ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> Total Alkalinity SM2320B-Titration ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> L30739-08 WG404177 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Sulfate M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> L30739-09 WG404177 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG404014 pH SM4500H+B ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> WG404177 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG404014 Total Alkalinity SM2320B-Titration ZW Method deviation. The sample was centrifuged prior to <br /> analysis due to high solid content. <br /> REPAD.15.06.05.01 <br /> L30739-1606131531 Page 16 of 21 <br /> � i <br />
The URL can be used to link to this page
Your browser does not support the video tag.