Name of Addressee <br />Page 2 <br />Date <br />Section 2.05.6 <br />1. Page 17 of the above referenced permit section refers to 1997 NOAA evaporation rates for, semi and <br />climates. Please clarify if the 1997 NOAA evaporation rate for, semi -arid climates is still applicable. <br />2. Page 19 of the above referenced permit section refers to effluent requirements specified in the NPDES <br />Permit. Please cite, in this paragraph where the NPDES Permit resides in the permit document. <br />3. Page 23 of the above referenced permit section refers to Figure 2.05.6(3)-1 and uses terminology (Dakota <br />Sandstone, low wall and dryland pasture) that does not appear on the figure. Please utilize the same <br />terminology on the figure as used in the discussion and update the figure as needed. Also, show on the <br />figure the direction of mining. <br />4. Please explain if NPDES 001 and SW -N3 were sampled for TDS and flow after 2000. Also, explain the <br />rational for, only averaging through the year 2000 if these monitoring sites have been sampled since 2000. <br />Section 4.05.4 (1-4) - Stream Channel Diversion and Channel Reconstruction <br />1. Please describe how the disturbance associated with the Meehan Draw crossing will be reclaimed when the <br />crossing structure is removed or cite the appropriate permit section with the reclamation plan. <br />Section 4.05.5 - Sediment Control Measures <br />1. Two irrigation systems are planned to be installed on the Garvey property to support the post -mining <br />land use. From Map 2.05.5-1 Post Mining Land Use, it appears that the irrigation tail water will be <br />directed to sediment ponds NHN-001 and NHN-002. Was the additional water from the irrigation <br />system considered in the SEDCAD modeling for the ditches and the ponds? <br />2. DRMS has not verified the SEDCAD provided in the PR -1 application because some of the adequacy <br />questions need clarifying. SEDCAD will be verified when the adequacy questions are answered. <br />Appendix 2.05.4(2)(e)-1 <br />1. On Map 2.05.4(2)(e)-1 it shows the irrigated pasture having 9" risers located on the west and south <br />boundary of the 18.8 acres. If the sideroll direction of travel is north to south then only the western <br />boundary of the area needs risers. Are risers being installed on both the west and south boundaries of <br />the irrigated pasture? <br />2. Map 2.05.4(2)(e)-1 shows the risers for the irrigated pasture are 9" and the text on page 2 of Appendix <br />2.05.4(2)(e)-1 states the risers are 4". Please clarify the size of the risers for the 18.8 acre irrigated <br />pasture. <br />3. The text on page 2 of Appendix 2.05.4(2)(e)-1 states that 4" risers will be spaced at 120' intervals for <br />the side roll irrigation supply line. Many side roll irrigation systems use a set pattern of 50' intervals <br />(or 3 wheel rotations) and therefore have risers spaced along the supply line at approximately 50'-60' <br />intervals. Please clarify that the distance between the supply line risers of 120' is appropriate for this <br />application. <br />If you have any questions or need additional information, please contact me at (303) 866-3567 ext. 8142. <br />