My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01-14_REPORT - M1980244 (15)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2016-01-14_REPORT - M1980244 (15)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 6:14:32 PM
Creation date
1/15/2016 2:27:31 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Report
Doc Date
1/14/2016
Doc Name
Final Report Quality Assurance Monitoring & Test Results
From
Cripple Creek & Victor Gold Mining Company
To
DRMS
Email Name
TC1
ERR
AME
WHE
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cripple Creek & Victor Gold Mining Company <br />Squaw Gulch VLF Phase 1 <br />(9,550-foot Elevation Bench to Geomembrane Panel P1635) <br />Final Report <br />Quality Assurance Monitoring & Test Results <br />January 2016 <br />s:\projects\1125n squaw valley\8.0 engineer-design\8.1 reports-docs\phase 1 roc report-9550 up\01.report text\phase 1 roc report.docx i <br />C ONT ENT S <br />1.0 INTRODUCTION .............................................................................................................................. 1 <br />1.1 Project Description .............................................................................................................. 2 <br />1.2 Construction Quality Assurance/Construction Quality Control ............................................ 3 <br /> CQA Monitoring of Earthworks ............................................................................... 3 <br /> CQA/CQC Monitoring of Geosynthetics Installation ............................................... 4 <br />1.3 Project Coordination ............................................................................................................ 5 <br /> Daily Construction Summary Reports .................................................................... 5 <br /> Weekly Construction Summary Reports ................................................................ 5 <br />1.4 Project Technical Specifications .......................................................................................... 6 <br />1.5 Record Survey Documentation ........................................................................................... 6 <br />1.6 Certification Boundary ......................................................................................................... 6 <br />2.0 SUMMARY OF EARTHWORK CONSTRUCTION ........................................................................... 7 <br />2.1 Underground Workings Remediation .................................................................................. 8 <br />2.2 Underdrains ......................................................................................................................... 8 <br /> Secondary Underdrain System .............................................................................. 8 <br /> Tertiary Underdrain System ................................................................................... 9 <br /> Geomembrane Installation of the Underdrain Ponds ............................................. 9 <br />2.3 Site Grading ......................................................................................................................... 9 <br />2.4 Subgrade Preparation ....................................................................................................... 10 <br />2.5 Leak Detection ................................................................................................................... 10 <br />2.6 Soil Liner Fill ...................................................................................................................... 10 <br />2.7 Project Composite Liner System ....................................................................................... 11 <br />2.8 High Volume Solution Collection System .......................................................................... 11 <br />2.9 Drain Cover Fill .................................................................................................................. 12 <br />3.0 GEOSYNTHETICS INSTALLATION .............................................................................................. 13 <br />3.1 Underdrain System ............................................................................................................ 13 <br />3.2 Leak Detection System ...................................................................................................... 13 <br /> 40-mil Smooth LLDPE Geomembrane ................................................................. 13 <br />3.3 Project Geomembrane Liner System ................................................................................ 13 <br />4.0 EARTHWORK CQA TESTING AND MONITORING...................................................................... 14 <br />4.1 Results of Laboratory Soils Testing ................................................................................... 14 <br /> Grain Size Distribution .......................................................................................... 15 <br /> Moisture Content .................................................................................................. 16 <br /> Atterberg Limits .................................................................................................... 16 <br /> Proctor Compaction Tests .................................................................................... 17 <br /> Permeability Tests ................................................................................................ 17 <br />4.2 Field Testing and Monitoring ............................................................................................. 18 <br /> Underdrains .......................................................................................................... 18 <br /> Structural Fill ......................................................................................................... 18 <br /> Soil Liner Fill ......................................................................................................... 18 <br /> Drain Cover Fill ..................................................................................................... 19 <br /> Temperature Monitoring ....................................................................................... 20 <br />5.0 GEOSYNTHETICS QC SUBMITTALS ........................................................................................... 21 <br />5.1 Geomembrane Installation Personnel Résumés ............................................................... 21 <br />5.2 Geomembrane QC Documents ......................................................................................... 21 <br /> Resin QC Certificates ........................................................................................... 21 <br /> Roll QC Certificates .............................................................................................. 21 <br /> Welding Rod QC Certificates ............................................................................... 22
The URL can be used to link to this page
Your browser does not support the video tag.