My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-12-29_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2015-12-29_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 6:13:55 PM
Creation date
12/30/2015 9:46:58 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
12/29/2015
Doc Name
4th Quarter 2015 Groundwater Sampling
From
Golder Associates
To
DRMS
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Inorganic <br />Reference <br />Report Header Explanations <br />Batch <br />Found <br />Limit <br />Lower <br />MDL <br />PCN/SCN <br />PQL <br />QC <br />Rec <br />RPD <br />Upper <br />Sample <br />A distinct set of samples analyzed at a specific time <br />Value of the QC Type of interest <br />Upper limit for RPD, in %. <br />Lower Recovery Limit, in % (except for LCSS, mg/Kg) <br />Method Detection Limit. Same as Minimum Reporting Limit unless omitted or equal to the PQL (see comment #5). <br />Allows for instrument and annual fluctuations. <br />A number assigned to reagents/standards to trace to the manufacturer's certificate of analysis <br />Practical Quantitation Unit. Synonymous with the EPA term "minimum lever. <br />True Value of the Control Sample or the amount added to the Spike <br />Recovered amount of the true value or spike added, in % (except for LCSS, mg/Kg) <br />Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Recovery Limit, in % (except for LCSS, mg/Kg) <br />Value of the Sample of interest <br />QC Sample Types <br />AS <br />ASD <br />CCB <br />CCV <br />DUP <br />ICB <br />ICV <br />ICSAB <br />LCSS <br />LCSSD <br />LCSW <br />Analytical Spike (Post Digestion) <br />Analytical Spice (Post Digestion) Duplicate <br />Continuing Calibration Blank <br />Continuing Calibration Verification standard <br />Sample Duplicate <br />Initial Calibration Blank <br />Initial Calbratbn Verification standard <br />Inter -element Correction Standard - A plus B solutions <br />Laboratory Control Sample - Soil <br />Laboratory Control Sample - Soil Duplicate <br />Laboratory Control Sample - Water <br />LCSWD <br />LFB <br />LFM <br />LFMD <br />LRB <br />MS <br />MSD <br />PBS <br />PBW <br />PQV <br />SDL <br />Laboratory Control Sample - Water Duplicate <br />Laboratory Fortified Blank <br />Laboratory Fortified Matrix <br />Laboratory Fortified Matra Duplicate <br />Laboratory Reagent Blank <br />Matrix Spike <br />Matrix Spike Duplicate <br />Prep Blank - Soli <br />Prep Blank - Water <br />Practical Quantitation Verification standard <br />Serial Dilution <br />QC Sample Type Explanations <br />Blanks <br />Control Samples <br />Duplicates <br />Spikes/Fortified Matrix <br />Standard <br />Verifies that there is no or minimal contamination in the prep method or calibration procedure. <br />Verifies the accuracy of the method, including the prep procedure. <br />Verifies the precision of the instrument and/or method. <br />Determines sample matrix interferences, lt any. <br />Verifies the validity of the calibration. <br />ACZ Qualifiers (Qua!) <br />B Analyte concentration detected at a value between MDL and PQL. The associated value is an estimated quantity. <br />H Analysis exceeded method hold time. pH is a field test with an immediate hold time. <br />L Target analyte response was below the laboratory defined negative threshold. <br />U The material was analyzed for, but was not detected above the level of the associated value. <br />The associated value is either the sample quantitation limit or the sample detection limit. <br />Method References <br />(1) <br />(2) <br />(3) <br />(4) <br />(5) <br />Comments <br />(1) <br />(2) <br />(3) <br />(4) <br />(5) <br />EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes, March 1983. <br />EPA 600/R-93-100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993. <br />EPA 600/R-94-111. Methods for the Determination of Metals in Environmental Samples - Supplement I, May 1994. <br />EPA SW -846. Test Methods for Evaluating Solid Waste. <br />Standard Methods for the Examination of Water and Wastewater. <br />QC results calculated from raw data. Results may vary slightly if the rounded values are used in the calculations. <br />Soft Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br />Animal matrices for Inorganic analyses are reported on an "as received' basis. <br />An asterisk in the "XQ' column indicates there is an extended qualifier and/or certification qualifier <br />associated with the result. <br />If the MDL equals the PQL or the MDL column is omitted, the PQL is the reporting limit. <br />For a complete list of ACZ's Extended Qualifiers, please click: http://www.acz.com/public/extquallist.pdf <br />REP001.03.15.02 <br />L27730-1511231527 <br />Page 11 of 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.