ADZ Laboratories, Inc. • - - • - <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 0 - e <br /> Rio Grande Silver, Inc. ACZ Project ID: L26557 <br /> .. <br /> L26567-01 WG390711 Iron,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Manganese,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG391064 Mercury,total M1631,Atomic Fluorescence Q5 Sample received with inadequate chemical preservation. <br /> Additional preservation performed by the laboratory. <br /> WG390371 Silica,total recoverable M200.7 ICP ZS Digestion procedures have the potential to trigger silica <br /> polymerization and precipitation,leading to low biased <br /> results. Silica chemistry is complex and polymerization <br /> kinetics are unpredictable. Dissolved and/or acid soluble <br /> silica analyses may provide more accurate measurements. <br /> WG390829 Silver,dissolved M200.8 ICP-MS BE Target analyte in continuing calibration blank(CCB)at or <br /> above the acceptance criteria. Target analyte was not <br /> detected in the sample[<MDL]. <br /> WG390944 Zinc,dissolved M200.8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG391353 Zinc,total recoverable M200.8 ICP-MS M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG390665 Carbon,dissolved organic(DOC) SM5310B RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG390370 Chemical Oxygen Demand M410.4 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390390 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390605 Fluoride SM450OF-C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDQ. <br /> WG390186 Nitrate/Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG390511 Nitrogen,ammonia M350.1 RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG390774 Nitrogen,total Kjeldahl M351.2-TKN by Block Digester RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390578 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390501 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390390 Sulfate M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG390634 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDQ. <br /> SM2320B-Titration RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density <br /> exceeded the method limits. Another duplicate in the batch <br /> was used to assess precision. Method required duplicate <br /> frequency was not met. <br /> REPAD.15.06.05.01 <br /> L26557-1510011525 Page 34 of 48 <br />