Laserfiche WebLink
JSmCmAftoup Analytical Report i of 1 <br />Client: <br />Analyte: <br />Prep Date: <br />Analysis Date: <br />Approved Method Source: <br />Prep ID: <br />Analytical Method ID: <br />Instrument: <br />Matrix: <br />Sample volume used: <br />Analyst: <br />Client ID <br />DIS 001A <br />SWAWD <br />Cotter Corporation <br />Cadmium, Cd — TR <br />06/17/2015 <br />06/21/2015 <br />40 CFR 136.3 <br />Std. Methods 3030 E. <br />USEPA 200.9 <br />iCE 3500, STPGFAA <br />Aqueous (water, wastewater, groundwater) <br />50 mL Dilution Factor: 1 <br />RK <br />Sma Date SCG # Results F11125 <br />06/16/2015 315377.A U <br />06/16/2015 315378.A U <br />Client: Cotter Corporation <br />Analyte: Sulfide, S2" <br />Prep Date: 06/18/2015 <br />Analysis Date: 06/18/2015 <br />Approved Method Source: 40 CFR 136.3 <br />Prep ID: Std. Methods 4500 SZ"G <br />Analytical Method ID: Std. Methods 4500 S2"G <br />Instrument: Orion DUAL STAR ISE Meter — Sulfide <br />Matrix: <br />Aqueous (water, wastewater, groundwater) <br />Sample volume used: <br />25 mL <br />Analyst: <br />RK <br />Client ID SmADate <br />SCG # Results Flags <br />DIS 001A 06/16/2015 <br />315377.A 0.172 J <br />SWAWD 06/16/2015 <br />315378.A 0.177 J <br />Qualifiers: <br />E — Extrapolated value. Value exceeds calibration range <br />H — Analysis exceeded holding time <br />J — Estimated value detected below the PQUMRL <br />S — Sp&c recovery outside acceptance limits <br />U — Analyte not detected <br />X — See case narrative <br />Confidential and Privileged <br />MDL POL Units <br />0.2 1.0 11911, <br />0.2 1.0 µg/L <br />MDL PPL Units <br />0.05 0.2 mg/L <br />0.05 0.2 mg/L <br />25 -Jun -15 <br />