My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-07-14_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2015-07-14_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 6:09:07 PM
Creation date
7/15/2015 4:53:58 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
7/14/2015
Doc Name
2nd Qtr Groundwater Sampling
From
Golder Assoc
To
DRMS
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />ADZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Golder Associates <br />L24573-01 WG384463 Chloride <br />L24573-02 WG384463 Chloride <br />Sulfate <br />I <br />L24573-03 WG384463 Chloride <br />' Sulfate <br />L24573-04 WG384463 Chloride <br />Sulfate <br />L24573-05 WG384463 Chloride <br />' L24573-06 WG384463 Chloride <br />Sulfate <br />L24573-07 WG384463 Chloride <br />' <br />Sulfate <br />L24573-08 WG384463 Chloride <br />' <br />L24573-09 WG384463 Chloride <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />REPAD.15.06.05.01 <br />M300.0 - Ion Chromatography <br />L24573-1506081348 <br />ACZ Project ID: L24573 <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M300.0 - Ion Chromatography <br />DC Sample required dilution. Non -target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Page 17 of 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.