Laserfiche WebLink
0 <br />11 <br />C <br />ED] <br />INSTALL SP -041 WITH EPDM GASKET <br />(PROVIDED) AT INNER & OUTER <br />WALL WITH WASHER & LOCK NUT <br />(PROVIDED) FOR TIGHT SEAL <br />NO <br />PLAN <br />SCALE: 3/"=l'-0:" <br />REVISIONS <br />REFERENCE DRAWINGS <br />ISSUE RECORD <br />DESCRIPTION <br />DATE <br />BY <br />CHK <br />APP <br />DRAWING NO <br />TITLE <br />DATE <br />ISS <br />REV <br />TO <br />30-800-19 <br />PUMPBACK WATER PIPELINE "F"'- PLAN & PROFILE <br />02-13-15 <br />1 <br />A <br />CLIENT <br />80-800-64 <br />PUMPBACK ENCL. GRND'G, LIGHTING, & POWER PLAN <br />04-02-15 <br />2 <br />B <br />CLIENT <br />30-800-23 <br />PUMPBACK PUMP ENCL. PLANS, SECTIONS & DETAILS <br />04-13-15 <br />3 <br />0 <br />CLIENT <br />PIPE WALL <br />GASKET- <br />LOCKING NUT <br />SECTION (1) <br />N.T.S. - 1480-800-055 <br />PUMPBACK TURBINE <br />VENT <br />1480-800-056 <br />PUMPBACK VENT <br />T/FLG 9263'-3" (REF) DAMPER <br />dDERDRAIN PIPE (EXIST.) <br />CUT & ADD FLG. <br />NG. 30-800-19 FOR CONTINUATION <br />N 2"x/2" RED. <br />FQI <br />DISCH. R <br />800 <br />2"0 'OUTLET EL: 9253'-10" IIISAMPLE <br />CONN. <br />PLTFM. EL. 9253'-12" — <br />6"0 O'FLOW EL. 9252_ — <br />DRILL Ya"0 <br />HOLE IN CAP <br />1Yz"-FW-88004-1 CA <br />1210-800-020- <br />PUMPBACK PUMP <br />LEVEL SENSOR—� <br />(NOTE 3) <br />Q'_� <br />(NOTE 3) <br />B/PUMP <br />T/CONC EL. 9245'-3" (REF) <br />ENG. <br />MGR. <br />a <br />2"x1Y" <br />RED TEE <br />1480-800-057 <br />PUMPBACK ELECTRIC <br />HEATER <br />(NOTE 2) <br />I <br />PUMPBACK MANUAL <br />LOUVER <br />2"x1Yz" <br />/ CONC, SWIG. <br />2"-FW-88003-1CA <br />��EL. 9257'-7)/4" <br />10"0 STD. SCH. TEE' <br />ELEVATION <br />(SEE PLAN FOR ORIENTATION) <br />(N.T.S.) <br />cc <br />&v <br />2'0 CMP <br />UNTENANCE LADDER <br />-FW-88006-1 CA <br />8"UNDERDRAIN (EXIST.) <br />FIELD CUT & ADD FLG. <br />8"0 INLET EL. 9253'-106/R" <br />(FIELD VERIFY] __ <br />GRADE EL. 9253-6"t (FIELD VERIF <br />° <br />"-FW-88003-1 CA <br />?10-800-019 <br />PUMPBACK PUMP <br />STEEL GRATING <br />SEE DWG. 30-800-23 <br />SAS -11 (TYP. 4) <br />FIELD DRILL CHANNELS AS REQ'D. <br />SEE DWG. 30-800-23 <br />9 <br />)TE 3) ° <br />° <br />° <br />SCALE <br />0 1 2 3 4 5 <br />(FEET) <br />3/4"=1'-0" <br />RECEIVED <br />JUN 24 2015 <br />DMSION OF RECLAMATION <br />MINING AND SAFETY <br />lVI- 1�1�0 _->_4'-F 2-0-40 <br />ISSUED <br />FOR CONSTRUCTION <br />04-13-15 <br />NOTES: <br />1, ALL PIPE PENETRATIONS IN CMP TO BE SEALED <br />WATERTIGHT. <br />2. CONTRACTOR TO PROVIDE STAND-OFF TO MOUNT <br />HEATER & CLEAR INSULATION. CONTRACTOR ALSO TO <br />PROVIDE ELECTRICAL PANEL SUPPORT BRACKETS PRIOR <br />TO INSULATING. <br />3. LEVEL ELEMENTS FURNISHED WITH PUMP & INSTALLED <br />BY CONTRACTOR, <br />4. PUMP IS SUSPENDED WITH Y6" S.S. CABLE (PROVIDED <br />W/ PUMP). CONTRACTOR TO PROVIDE SUPPORT TO <br />ATTACH CABLE. <br />FOSTER WHEELER <br />CRIPPLE CREEK & VICTOR Tw SALT LAKE CITY, UTAH <br />GOLD MINING, COMPANY TITLE SQUAW GULCH ADR2 <br />SQUAW GULCH ADR2 PUMPBACK AREA <br />PUMPBACK PUMP ENCLOSURE <br />PLAN AND ELEVATION <br />THIS DRAWING IS THE PROPERTY OF FOSTER WHEELER USA CORPORATION AND IS LENT WITHOUT CONSIDERATION FOR CC&V VI <br />OTHER THAN THE BORROWER'S AGREEMENT THAT IT SHALL NOT BE REPRODUCED, COPIED, LENT OR DISPOSED OF DWG SIZE SCALE PROJECT NO DRAWING NO <br />DIRECTLY OR UDIRECTLY. NOR USED FOR ANY RNISHED. ANY APPARATUS SHOWNIN�THE DRAWINGS CSE OTHER THAN Q ERED BYT FOR HIPAT NTS SPECIFICALLY D NOTED 134031 60-800-20 <br />CO. <br />REV <br />0 <br />A <br />B <br />D <br />ENGINEER RECORD <br />FOR <br />BY DATE <br />APPROVAL <br />DRAWN CMS 01-21-1 <br />APPROVAL <br />CHECKED MIT 01-27-1 <br />ENGINEER <br />CONSTRUCTION <br />LEAD ENGINEER <br />ENG. <br />MGR. <br />a <br />2"x1Y" <br />RED TEE <br />1480-800-057 <br />PUMPBACK ELECTRIC <br />HEATER <br />(NOTE 2) <br />I <br />PUMPBACK MANUAL <br />LOUVER <br />2"x1Yz" <br />/ CONC, SWIG. <br />2"-FW-88003-1CA <br />��EL. 9257'-7)/4" <br />10"0 STD. SCH. TEE' <br />ELEVATION <br />(SEE PLAN FOR ORIENTATION) <br />(N.T.S.) <br />cc <br />&v <br />2'0 CMP <br />UNTENANCE LADDER <br />-FW-88006-1 CA <br />8"UNDERDRAIN (EXIST.) <br />FIELD CUT & ADD FLG. <br />8"0 INLET EL. 9253'-106/R" <br />(FIELD VERIFY] __ <br />GRADE EL. 9253-6"t (FIELD VERIF <br />° <br />"-FW-88003-1 CA <br />?10-800-019 <br />PUMPBACK PUMP <br />STEEL GRATING <br />SEE DWG. 30-800-23 <br />SAS -11 (TYP. 4) <br />FIELD DRILL CHANNELS AS REQ'D. <br />SEE DWG. 30-800-23 <br />9 <br />)TE 3) ° <br />° <br />° <br />SCALE <br />0 1 2 3 4 5 <br />(FEET) <br />3/4"=1'-0" <br />RECEIVED <br />JUN 24 2015 <br />DMSION OF RECLAMATION <br />MINING AND SAFETY <br />lVI- 1�1�0 _->_4'-F 2-0-40 <br />ISSUED <br />FOR CONSTRUCTION <br />04-13-15 <br />NOTES: <br />1, ALL PIPE PENETRATIONS IN CMP TO BE SEALED <br />WATERTIGHT. <br />2. CONTRACTOR TO PROVIDE STAND-OFF TO MOUNT <br />HEATER & CLEAR INSULATION. CONTRACTOR ALSO TO <br />PROVIDE ELECTRICAL PANEL SUPPORT BRACKETS PRIOR <br />TO INSULATING. <br />3. LEVEL ELEMENTS FURNISHED WITH PUMP & INSTALLED <br />BY CONTRACTOR, <br />4. PUMP IS SUSPENDED WITH Y6" S.S. CABLE (PROVIDED <br />W/ PUMP). CONTRACTOR TO PROVIDE SUPPORT TO <br />ATTACH CABLE. <br />FOSTER WHEELER <br />CRIPPLE CREEK & VICTOR Tw SALT LAKE CITY, UTAH <br />GOLD MINING, COMPANY TITLE SQUAW GULCH ADR2 <br />SQUAW GULCH ADR2 PUMPBACK AREA <br />PUMPBACK PUMP ENCLOSURE <br />PLAN AND ELEVATION <br />THIS DRAWING IS THE PROPERTY OF FOSTER WHEELER USA CORPORATION AND IS LENT WITHOUT CONSIDERATION FOR CC&V VI <br />OTHER THAN THE BORROWER'S AGREEMENT THAT IT SHALL NOT BE REPRODUCED, COPIED, LENT OR DISPOSED OF DWG SIZE SCALE PROJECT NO DRAWING NO <br />DIRECTLY OR UDIRECTLY. NOR USED FOR ANY RNISHED. ANY APPARATUS SHOWNIN�THE DRAWINGS CSE OTHER THAN Q ERED BYT FOR HIPAT NTS SPECIFICALLY D NOTED 134031 60-800-20 <br />CO. <br />REV <br />0 <br />A <br />B <br />D <br />