Laserfiche WebLink
Culvert T -F4 <br />Manning's Equation <br />Flow In a 30" Half Culvert <br />Flow Depth D 0.30 <br />Slope S 0.33 <br />Mannings "N" N 0.015 <br />AREA = Number Derived in AutoCad <br />WETTED PERIMETER= (2*Pi*r)/2 <br />Number derived in AutoCad <br />R=AREANVETTED PERIMETER <br />V=(1.49/N)*(R11.667)*(S^.5)= <br />Q=AXV= <br />Q REQUIRED - Peak Discharge <br />I * Flow derived from 5.0 Ac. drainage area, CN=90 <br />Feet <br />Express as Decimal <br />Express as Decimal <br />0.34 FEET ^2 <br />1.78 FEET <br />[isit'7 <br />18.93 FT/SEC <br />6.43 CFS <br />4.74 CFS <br />Culvert T -F4 <br />Manning's Equation <br />Flow In a Trapezoidal "Smart Ditch" Channel <br />Depth <br />D <br />0.3 <br />Feet <br />Width <br />W <br />1.12 <br />Feet <br />Slope <br />S <br />0.33 <br />Express as Decimal <br />Mannings "N" <br />N <br />0.022 <br />Express as Decimal <br />Side Slope <br />X <br />1.3 <br />Slope = X:1 <br />AREA=(W*D)+(X*D^2)= <br />0.45 <br />FEET ^2 <br />WETTED PERIMETER=(W)+2*[((X*D)^2+D^2)^0.5] <br />2.10 <br />FEET <br />R=AREANVETTED PERIMETER <br />0.22 <br />V=(1.49/N)*(R^.667)*(S".5)= <br />13.98 <br />FT/SEC <br />Q=AXV= <br />6.33 <br />CFS <br />Q REQUIRED - Peak Discharge <br />4.74 <br />CFS <br />TR -91 App. B-106 11/14 <br />