Laserfiche WebLink
Client: <br />Project: <br />Analyte <br />Trustour People. Trust our Data. Billings, MT 800.735.4489 • Casper, WY 888.235.0515 <br />`E College Station. TX 888.690.2218 • Gillette, WY 866.686.7175 • Helena. MT 877.472.0711 <br />QA/QC Summary Report <br />Prepared by Casper, WY Branch <br />Cotter Corporation Report Date: 05/07/15 <br />Schwartz - GW 4/14/15 S27854, S27857 Work Order: C15040486 <br />Count Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br />Method: <br />E200.8 <br />6 Method Blank <br />85 <br />Antimony <br />ND <br />Analytical Run: ICPMS2-C_150421A <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />ND <br />mg/L <br />Lead <br />04/21/15 13:44 <br />Antimony <br />Silver <br />ND <br />0.0500 mg/L 0.0010 <br />100 <br />90 <br />110 <br />Lab ID: LCS3-44432 <br />Copper <br />Antimony <br />0.493 <br />0.0516 mg/L 0.0010 <br />103 <br />90 <br />110 <br />Copper <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />mg/L <br />Silver <br />0.0531 <br />04/21/15 16:09 <br />Antimony <br />0.496 <br />mg/L <br />0.0504 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Copper <br />0.0517 mg/L 0.0010 <br />103 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/21/15 17:27 <br />Antimony <br />0.0513 mg/L 0.0010 <br />103 <br />90 <br />110 <br />Copper <br />0.0527 mg/L 0.0010 <br />105 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/21/15 19:59 <br />Antimony <br />0.0488 mg/L 0.0010 <br />98 <br />90 <br />110 <br />Copper <br />0.0507 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/21/15 22:45 <br />Antimony <br />0.0504 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Copper <br />0.0510 mg/L 0.0010 <br />102 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/22/15 01:16 <br />Antimony <br />0.0506 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Copper <br />0.0504 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/22/15 03:53 <br />Antimony <br />0.0512 mg/L 0.0010 <br />102 <br />90 <br />110 <br />Copper <br />0.0507 mg/L 0.0010 <br />101 <br />90 <br />110 <br />Lab ID: <br />ICV <br />2 <br />Initial Calibration Verification Standard <br />04/22/15 06:29 <br />Antimony <br />0.0511 mg/L 0.0010 <br />102 <br />90 <br />110 <br />Copper <br />0.0499 mg/L 0.0010 <br />100 <br />90 <br />110 <br />Method: E200.8 <br />Run: ICPMS2-C_150421A <br />Lab ID: MB -44432 <br />6 Method Blank <br />85 <br />Antimony <br />ND <br />mg/L <br />Arsenic <br />0.0005 <br />mg/L <br />Copper <br />ND <br />mg/L <br />Lead <br />3E-05 <br />mg/L <br />Silver <br />ND <br />mg/L <br />Thallium <br />ND <br />mg/L <br />Lab ID: LCS3-44432 <br />6 Laboratory Control Sample <br />Antimony <br />0.493 <br />mg/L <br />Arsenic <br />0.490 <br />mg/L <br />Copper <br />0.483 <br />mg/L <br />Lead <br />0.496 <br />mg/L <br />Silver <br />0.0531 <br />mg/L <br />Thallium <br />0.496 <br />mg/L <br />Qualifiers: <br />RL - Analyte reporting limit. <br />MDC - Minimum detectable concentration <br />Run: ICPMS2-C 150421A <br />0.0002 <br />0.0003 <br />0.0004 <br />3E-05 <br />2E-05 <br />0.0001 <br />ND - Not detected at the reporting limit <br />Batch: 44432 <br />04/21/15 16:25 <br />04/21/15 16:28 <br />Page 14 of 30 <br />Run: ICPMS2-C_150421A <br />0.0010 <br />99 <br />85 <br />115 <br />0.0010 <br />98 <br />85 <br />115 <br />0.0050 <br />97 <br />85 <br />115 <br />0.0010 <br />99 <br />85 <br />115 <br />0.0010 <br />106 <br />85 <br />115 <br />0.00050 <br />99 <br />85 <br />115 <br />ND - Not detected at the reporting limit <br />Batch: 44432 <br />04/21/15 16:25 <br />04/21/15 16:28 <br />Page 14 of 30 <br />