ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 <br />Fortune Revenue Silver Mines Inc ACZ Project ID: L23570 <br />ID WORKNUM PARAMETER <br />METHODACZ <br />QUAL <br />DESCRIPTION <br />L23570-01 WG381463 Total Hot Plate Digestion <br />M200.2 ICP -MS <br />DJ <br />Sample dilution required due to insufficient sample. <br />WG381490 Lead, total <br />M200.8 ICP -MS <br />BB <br />Target analyte detected in calibration blank at or above <br />acceptance limit. Sample value was > 1 OX the <br />concentration in the calibration blank. <br />WG381437 Manganese, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG381758 Mercury, total <br />M245.1 CVAA <br />DJ <br />Sample dilution required due to insufficient sample. <br />WG381437 Zinc, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG381630 Chloride <br />SM4500CI-E <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG381609 Cyanide, total <br />M335.4 - Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG381788 Cyanide, WAD <br />SM4500-CN I -Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />WG381289 Dissolved Chromium, Hexavalent <br />SM3500Cr-B <br />HE <br />Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />SM3500Cr-B <br />QD <br />Reported value is the background -corrected concentration, <br />as described by the method. <br />SM3500Cr-B <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG381557 Fluoride <br />SM450OF-C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG381823 Nitrate/Nitrite as N <br />M353.2 - H2SO4 preserved <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG381341 Phosphorus, ortho dissolved <br />M365.1 - Automated Ascorbic <br />QP <br />The sample was filtered at the laboratory more than 15 <br />Acid <br />minutes after sample collection. For Orthophosphate, 40 <br />CFR Part 136.3 requires filtration within 15 minutes of <br />collection. <br />M365.1 - Automated Ascorbic <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />Acid <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M365.1 - Automated Ascorbic <br />ZU <br />Analysis date/time preceeds filter date/time. A portion of <br />Acid <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />WG381482 Residue, Filterable (TDS) @180C <br />SM2540C <br />N1 <br />See Case Narrative. <br />WG381721 Sulfate <br />D516-02/-07 - Turbidimetric <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />REPAD.15.06.05.01 <br />L23570-1504141515 Page 20 of 30 <br />