My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-04-10_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2015-04-10_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:59:11 PM
Creation date
4/13/2015 12:16:14 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
4/10/2015
Doc Name
First Quarter 2015 Groundwater Sampling at Boettcher Quarry
From
Golder Associates
To
DRMS
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Golder Associates ACZ Project ID: L22988 <br />WORKNUM <br />PARAMETER <br />METHOD <br />QUAL <br />DESCRIPTION <br />L22988 -01 WG379380 <br />Sodium, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />or LFB) was acceptable. <br />WG379451 <br />Chloride <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />validation because the sample concentration is too low for <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />accurate evaluation (< 10x MDL). <br />L22988 -04 WG379735 <br />validation because the sample concentration is too low for <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />accurate evaluation (< 10x MDL). <br />WG379395 <br />pH <br />SM4500H+ B <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content. <br />Total Alkalinity <br />SM2320B - Titration <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />Sample required dilution. Non - target analyte exceeded <br />analysis due to high solid content. <br />L22988 -02 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />' <br />validation because the sample concentration is too low for <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />Sulfate <br />M300.0 - Ion Chromatography <br />calibration range. <br />L22988 -03 WG379380 <br />Sodium, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />L22988 -04 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />L22988 -05 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />' <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />L22988 -06 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />calibration range. <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />L22988 -07 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />1 <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG379395 <br />pH <br />SM4500H+ B <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content. <br />Total Alkalinity <br />SM2320B - Titration <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content. <br />L22988 -08 WG379735 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG379395 <br />pH <br />SM4500H+ B <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content. <br />WG379735 <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />WG379395 <br />Total Alkalinity <br />SM2320B - Titration <br />ZW <br />Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content. <br />REPAD.15.06.05.01 <br />L22988- 1503051058 <br />Page 17 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.