Laserfiche WebLink
ADZ Laboratories, Inc. <br />Ept;1t, <br />�Ik <br />2773 Downhill Drive Steamboat Springs, CO 80487 <br />(800) 334 -5493 <br />, <br />Golder Associates <br />ACZ Project ID: <br />L22988 <br />Potassium, dissolved <br />M200.7 ICP <br />1ACZ ID Type <br />Analyzed <br />PCN/SCN <br />Qc <br />Sample <br />Found <br />Units <br />Rec <br />Lower <br />Upper <br />RPD Limit Qual <br />WG379380 <br />WG3793801CV ICV <br />02/23/15 20:20 <br />11150219 -1 <br />20 <br />19.36 <br />mg /L <br />97 <br />95 <br />105 <br />WG379380ICB ICB <br />02123/15 20:26 <br />U <br />mg /L <br />-0.6 <br />0.6 <br />WG379380LFB LFB <br />02/23/15 20:38 <br />11150218 -2 <br />98.07852 <br />96.26 <br />mg /L <br />98 <br />85 <br />115 <br />L22988 -04AS AS <br />02/23/15 21:37 <br />11150218 -2 <br />98.07852 <br />4 <br />99.57 <br />m9 /L <br />97 <br />85 <br />115 <br />L22988 -04ASD ASD <br />02/23/15 21:41 <br />11150218 -2 <br />98.07852 <br />4 <br />101.4 <br />mg /L <br />99 <br />85 <br />115 <br />2 20 <br />WG379443 <br />WG3794431CV ICV <br />02/24/1511:54 <br />11150219 -1 <br />20 <br />19.53 <br />mg /L <br />98 <br />95 <br />105 <br />WG379443ICB ICB <br />02/24/1512:00 <br />U <br />mg /L <br />-0.6 <br />0.6 <br />WG379443LFB LFB <br />02/24/1512:13 <br />11150218 -2 <br />98.07852 <br />98.09 <br />mg /L <br />100 <br />85 <br />115 <br />L22988 -04AS AS <br />02/24/1513:09 <br />11150218 -2 <br />196.15704 <br />4 <br />196.4 <br />mg /L <br />98 <br />85 <br />115 <br />L22988 -04ASD ASD <br />02/24/1513:12 <br />11150218 -2 <br />196.15704 <br />4 <br />196.18 <br />mg /L <br />98 <br />85 <br />115 <br />0 20 <br />1 <br />Residue, Filterable (TDS) @180C <br />SM2540C <br />ACZ ID Type <br />WG379366 <br />Analyzed <br />PCN/SCN <br />Oc <br />Sample <br />Found <br />Units <br />Rec <br />Lower <br />Upper <br />RPD Limit Qual <br />WG379366PBW PBW <br />02/23/1510:45 <br />U <br />m9 /L <br />-20 <br />20 <br />WG379366LCSW LCSW <br />02/23/1510:46 <br />PCN47859 <br />260 <br />250 <br />mg /L <br />96 <br />80 <br />120 <br />L22988 -07DUP DUP <br />02/23/1511:00 <br />7380 <br />7520 <br />mg /L <br />2 10 <br />L23006 -02DUP DUP <br />02/23/1511:14 <br />136 <br />140 <br />mg /L <br />3 10 <br />Sodium, dissolved <br />M200.7 ICP <br />,ACZ ID Type <br />Analyzed <br />PCN/SCN <br />Qc <br />Sample <br />Found <br />Units <br />Rec <br />Lower <br />Upper <br />RPD Limit Qual <br />WG379380 <br />WG3793801CV ICV <br />02/23/15 20:20 <br />11150219 -1 <br />100 <br />95.07 <br />mg /L <br />95 <br />95 <br />105 <br />WG379380ICB ICB <br />02/23/15 20:26 <br />U <br />mg /L <br />-0.6 <br />0.6 <br />WG379380LFB LFB <br />02/23/15 20:38 <br />11150218 -2 <br />100.0589 <br />97.34 <br />mg /L <br />97 <br />85 <br />115 <br />L22988 -04AS AS <br />02/23/15 21:37 <br />11150218 -2 <br />100.0589 <br />1480 <br />1463 <br />mg /L <br />-17 <br />85 <br />115 <br />M3 <br />L22988 -04ASD ASD <br />02/23/15 21:41 <br />11150218 -2 <br />100.0589 <br />1480 <br />1503 <br />mg /L <br />23 <br />85 <br />115 <br />3 20 M3 <br />WG379443 <br />WG3794431CV ICV <br />02/24/1511:54 <br />11150219 -1 <br />100 <br />96.09 <br />mg /L <br />96 <br />95 <br />105 <br />WG379443ICB ICB <br />02/24/1512:00 <br />U <br />mg /L <br />-0.6 <br />0.6 <br />WG379443LFB LFB <br />02/24/1512:13 <br />11150218 -2 <br />100.0589 <br />99.09 <br />mg /L <br />99 <br />85 <br />115 <br />L22988 -04AS AS <br />02/24/1513:09 <br />11150218 -2 <br />200.1178 <br />1430 <br />1634.6 <br />mg /L <br />102 <br />85 <br />115 <br />L22988 -04ASD ASD <br />02/24/1513:12 <br />11150218 -2 <br />200.1178 <br />1430 <br />1618.8 <br />mg /L <br />94 <br />85 <br />115 <br />1 20 <br />L22988- 1503051058 <br />Page 15 22 <br />of <br />