My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-03-31_REPORT - C1982057 (3)
DRMS
>
Day Forward
>
Report
>
Coal
>
C1982057
>
2015-03-31_REPORT - C1982057 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2017 10:17:23 AM
Creation date
4/1/2015 9:29:06 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1982057
IBM Index Class Name
Report
Doc Date
3/31/2015
From
Seneca Coal Company, LLC
To
DRMS
Annual Report Year
2014
Permit Index Doc Type
Annual Reclamation Report
Email Name
JHB
MPB
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CHRONOLOGICAL HISTORY OF REVEGETATION & BOND RELEASE <br />As of 2014 all disturbed areas not deemed permanent have <br />been seeded. Total areas seeded and revegetated prior to 2014 <br />are shown on 2012 annual reclamation report Chronological <br />Seeding Map. SCC submitted SL -5 requesting Phase II bond <br />release on eligible areas. Phase II release was approved on <br />approximately 798 acres (as shown in Figure 2). <br />The Report of Findings for Revegetation Success for Phase II <br />Bond Release will be submitted separately. <br />SEDIMENTATION POND SURVEYS <br />SCC is required by Permit C -82 -057 to monitor sedimentation <br />ponds for sediment storage capacities. This monitoring is <br />conducted by physically surveying each pond each year. This <br />schedule provides a sediment yield history and gives advanced <br />warning to operations personnel when sediment clean out work <br />is needed. Also, in accordance with Rule 4.05.6(11)(c), SCC <br />visually inspects each pond, at a minimum, quarterly each year. <br />During these inspections, any drastic change in sediment <br />storage /sudden increase in a sediment delta at the inlet of the <br />pond would be detected and mitigation implemented, if <br />necessary. <br />The results of the 2014 annual survey indicated that all ponds <br />are above the minimum requirement for storage and are shown <br />below on Table 13.3, Sediment Pond Capacities. <br />Figure 2: Phase II Bond Release Area (798 <br />acres <br />TABLE 13.3 SENEC - SEDIMENT PONDS - WATER CAPACITY TRENDS <br />YEAR <br />21309 <br />2009 <br />201!] <br />2011 <br />2012 <br />2613 <br />2014 <br />II -W - 003 <br />1.8 <br />= <br />4.9 <br />4 -9 <br />4.3 <br />43 <br />4 <br />J.3 <br />TR -39 <br />II -W - 006 <br />4.44 <br />4.8 <br />J.3 <br />5-3 <br />53 <br />5,3 <br />5-3 <br />5.9 <br />2120,'2004 <br />II -W - 009 <br />4,35 <br />72 <br />-.3 <br />7-3 <br />6.6 <br />6.6 <br />7 <br />6.8 <br />7/10/1992 <br />II -W - 015 <br />2.41 <br />2.8 <br />2.9 <br />3 <br />2.8 <br />2.9 <br />2-7 <br />2.6 <br />5/24 {2000 <br />II -W - 016 <br />2.804 <br />33 <br />3.- <br />3.9 <br />18 <br />3.8 <br />37 <br />33 <br />TR -73 6111 <br />II -W - 017 <br />1.68 <br />5.6 <br />5.6 <br />5.4 <br />4.8 <br />4.7 <br />_ - <br />11. <br />8/1/2003 <br />f ?J Bdo�.SEDC.42.� rrr�rlirfvra ?0�}r/24 hr �aorsnr ��a�r� <br />f2� Rang capacidy br,�u•�rirrapals�5id. or ari�iic¢ <br />STOCK TANKS <br />No new stock tanks were constructed in 2013. <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.