Laserfiche WebLink
Martin Marietta Materials <br />Spec -Agg 2015 Annual Report <br />shifts in representative orientations of the observed discontinuity sets based on our evaluation of the new <br />data. As discussed above, joint set P -7 represents a new representative discontinuity orientation based <br />on a relatively tight clustering of joint measurements centered in a distinct orientation not well represented <br />by the previously recognized sets. <br />In the 2015 annual report, a total of nine (9) representative discontinuity sets were identified and analyzed <br />for the structural discontinuity analyses. Representative discontinuity orientations used for this annual <br />report are shown in Figure 7 and summarized in Table 1 below. Foliation F -1 and F -2 are slightly shifted <br />but in general in line with previous reports. Joint sets P -2 and P -6 were observed as dominant joint sets <br />in a relatively tight clustering of joint measurements in the Southern Expansion Area. Joint set P -7 was <br />again observed in the Southern Expansion Area. Only a few P -1 and P -5 measurements were observed <br />to change /shift the orientation. We have tailored our kinematic analyses to these observations, such that <br />joint sets that were not observed in a particular area are not considered in kinematic analyses for walls <br />that line those areas. <br />Table 1: Representative Discontinuity Orientations <br />Discontinuity Set <br />Representative Orientation (Dip /Dip Direction) <br />2013 Annual Report <br />2014 Annual Report <br />2015 Annual Report <br />F -1 (Foliation) <br />43 0/1820 <br />33 0/170° <br />34 0/1700 <br />F -2 (Foliation) <br />13 0/2240 <br />22 0/2570 <br />24 0/2500 <br />F -3 (Foliation) <br />Not observed <br />Not observed <br />Not observed <br />P -1 (Joint) <br />74 0/172° (unchanged) <br />74 0/172° (unchanged) <br />74 0/1720 (unchanged) <br />P -2 (Joint) <br />55 0/0840 <br />59 0/870 <br />56 0/840 <br />P -3 (Joint) <br />51 0/264° <br />68 0/2550 <br />68 0/2560 <br />P-4 (Joint) <br />67 0/301 ° (Main Pit) <br />670/3010 <br />72 0/2990 <br />P -5 (Joint) <br />Not observed <br />68 0/3540 <br />68 0/3540 (unchanged) <br />P -6 (Joint) <br />66 °/051 ° (SEA)* <br />59 0/250 <br />60 0/240 <br />P -7 (Joint) <br />55 0/2130 <br />63 0/2200 <br />65 0/2150 <br />" SEA = Southern Expansion Area <br />6.2 Slope Geometry <br />Wall orientations used in this report are based on the mine plan developed by Martin Marietta in <br />December, 2003 (Figure 2). As discussed in the 2013 annual report, we used the same wall orientations <br />for our analyses that have been used since the 2003 report; however, we added several additional wall <br />orientations and modified the wall designations slightly. The new and former wall designations, slope <br />angles, and slope dip directions used to represent the final quarry walls are presented in Table 2 below. <br />February 25, 2015 Page 9 Lachel & Associates, Inc. <br />Project 14364006 00 02015 All Rights Reserved <br />