My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-02-26_REPORT - C1981028
DRMS
>
Day Forward
>
Report
>
Coal
>
C1981028
>
2015-02-26_REPORT - C1981028
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2017 10:35:21 AM
Creation date
2/26/2015 12:49:22 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981028
IBM Index Class Name
Report
Doc Date
2/26/2015
Doc Name
Annual Hydrology and Reclamation Report
From
Coors Energy Company
To
DRMS
Annual Report Year
2014
Permit Index Doc Type
Hydrology Report
Email Name
TNL
DIH
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Client: Coors Energy Company <br />Project/Site: Coors - Keenesburg Mine, CO 80643 <br />Job ID: 280 - 54414 -1 <br />Laboratory: TestAmerica Denver <br />Narrative <br />Case Narrative <br />CASE NARRATIVE <br />Client: Coors Energy Company <br />Project: Keenesburg Mine, CO <br />Report Number: 280 - 54414 -1 <br />TestAmerica Job ID: 280 - 54414 -1 <br />With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no <br />problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established <br />control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within <br />the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were <br />diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required. <br />Calculations are performed before rounding to avoid round -off errors in calculated results. <br />All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed <br />in the individual sections below. <br />RECEIPT <br />The samples were received on 4/17/2014 3:15 PM; the samples arrived in good condition, properly preserved and, where required, <br />on ice. The temperature of the cooler at receipt was 0.8° C. <br />No anomalies were encountered during sample receipt. <br />DISSOLVED METALS OCP) <br />The MS /MSD associated with prep batch 280 - 221479 exhibited spike recoveries outside QC control limits for Sodium. The <br />presence of the '4' qualifier in the report indicates analytes where the concentration in the unspiked sample exceeded four times <br />the spiking amount. The associated LCS was in control and demonstrates that operating procedures were in control. No further <br />action was required. <br />The laboratory control sample (LCS) associated with prep batch 280 - 222216 recovered outside control limits for Arsenic, Cadmium <br />and Molybdenum in analytical batch 280 - 222650. These analytes were biased high in the LCS and were not detected in the <br />associated samples; therefore, corrective action was deemed unnecessary. <br />The MS /MSD associated with prep batch 280 - 222216, performed on sample SMW -2 (280- 54414 -6) exhibited spike recoveries <br />outside QC control limits for several analytes. The presence of the A' qualifier in the report indicates analytes where the <br />concentration in the unspiked sample exceeded four times the spiking amount. The associated LCS was in control and <br />demonstrates that operating procedures were in control. No further action was required. <br />The continuing calibration verification (CCV) associated with batch 280 - 222216 recovered above the upper control limit for low <br />Sodium in analytical batch 280 - 222650. The sample associated with this CCV was non - detect for the affected analyte; therefore, <br />corrective action was deemed unnecessary. All other samples have been reported from the high Sodium line, which was within <br />established control limits. <br />The continuing calibration verification (CCV) associated with batch 280 - 222216 recovered above the upper control limit for <br />Molybdenum and Lead in analytical batch 280 - 222650. The samples associated with this CCV were non - detect for the affected <br />analytes; therefore, corrective action was deemed unnecessary. <br />No anomalies were observed. <br />TestAmerica Denver <br />Page 3 of 34 5/6/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.