Laserfiche WebLink
(545138) <br />being used. Long -term storage is impossible without decomposition. Only use containers made from tinted glass, <br />polyethylene & FRP. Keep out of reach of children. <br />PROCESS HAZARDS: Not Available <br />STORAGE TEMPERATURE: Store containers below 29 °C and above freezing point. Do not expose sealed containers <br />above 40 °C. Try to store in the dark at the lowest possible temperature, but keep from freezing, to slow -down decomposition. <br />SECTION 12 EXPOSURE CONTROLS /PERSONAL PROTECTION <br />ENGINEERING CONTROLS: Full handling precautions should be taken at all times. Provide good room ventilation plus <br />local exhaust at points of emission and low level floor exhaust in immediate handling area. Where engineering controls are not <br />feasible, use adequate local exhaust ventilation wherever mist, spray or vapor may be generated. <br />PERSONAL PROTECTIVE EQUIPMENT: <br />Eye: Use chemical safety goggles when there is potential for contact (splashing), faceshield recommended — <br />ANSI Z87.1 <br />Skin: Gloves and protective clothing (apron, boots, and bodysuits) made from rubber, vinyl, neoprene or PVC. <br />Standard work clothing closed at the neck and wrist while wearing impervious equipment. <br />Respiratory (Specify Type): A NIOSH /MSHA approved air purifying respirator with an acid gas cartridge or <br />canister may be permissible under circumstances where airborne concentrations are expected to exceed <br />exposure limits. Protection provided by air purifying respirators is limited. Use a positive pressure air <br />supplied respirator if there is potential for uncontrolled releases, exposure levels are not known, or other <br />circumstances where air purifying respirators may not provide adequate protection. <br />Other: Eyewash, shower station (ANSI Z358.1) must be provided within the immediate work area. <br />SECTION 13 ACCIDENTAL RELEASE MEASURES <br />Ventilate enclosed area. Collect product for recovery or disposal. For release to land, contain discharge by constructing dikes <br />or applying inert absorbent; for release to water, utilize damming and /or water diversion to reduce the spread of contamination; <br />and, for release to air, vapors may be suppressed by the use of a water fog. All run -off water must be captured for treatment <br />and disposal. Collect contaminated soil and water, and absorbent for disposal. Notify applicable government authority if <br />release is reportable or could adversely affect the environment. Please follow all Local, State and Federal Laws for clean -up <br />and disposal of all contaminated material. Deactivating Chemicals: Sodium Sulfite, Sodium Thiosulfate and Sodium <br />Bisulfite. <br />SECTION 14 REGULATORY INFORMATION <br />OSHA CLASSIFICATION, 29 CFR 41900 -1910: <br />Physical Hazards: Reactivity Health Hazards: Acute - Skin Sensitizer, Corrosive <br />CERCLA AND SARA REGULATIONS, 40 CFR 4300 -373: <br />Reportable Quantity = 100 lb. CERCLA Hazardous Material: Yes <br />Title III Hazard Classifications: Acute - yes, Chronic - no, Fire - yes, Reactivity - yes & Sudden Release of <br />Pressure - No. This product may be reportable under the requirements of 40 CFR §370. <br />SARA Extremely Hazardous Substance: No SARA Toxic Chemical: No CA Prop 65: No <br />FDA 21 CFR 178.1010: Yes, Approved as Sanitizer <br />NSF Whitebook (former USDA Approval) Listing: Aqua Guard Chlorinating Sanitizer 10.5% - 3D, 61, B2, <br />D1, D2, G4, G7, GX, Q4, Aqua Guard Bleach 12.5% - 3D, 131, 132, D1, D2, G4, GX, Q4 <br />EPA "CLEAN AIR ACT ": This product does not contain nor is it manufactured with ozone depleting substances. It is not <br />defined as a Hazardous Air Pollutant per 40 CFR 112. <br />EPA Pesticide: The 10.5% and 12.5% sodium hypochlorite products are registered with the U.S. EPA as a pesticide, as <br />required under the Federal Insecticide, Fungicide and Rodenticide Act ( FIFRA). It is a violation of Federal law to use this <br />product for pesticidal applications in a manner inconsistent with the FIFRA labeling. <br />NPCA -HMIS RATING: HEALTH: 3 FLAMMABILITY: 0 REACTIVITY: 2 <br />NFPA RATING:NONE AT THIS TIME <br />SECTION 15 REFERENCES <br />Suppliers' Material Safety Data Sheets and EPA Labeling Requirements <br />Olin and OxyChem Sodium Hypochlorite Handbook <br />Chlorine Institute Sodium Hypochlorite Pamphlet #96 <br />Chlorine Institute Product Stewardship Bulletins for Sodium Hypochlorite <br />This information contained herein, while not guaranteed, is offered only as a guide to the handling of this specific material and has been <br />prepared in good faith by product knowledgeable personnel. This information is not intended to be all- inclusive as to the manner and <br />conditions of use, handling and storage. Other factors may involve other or additional safety or performance considerations. Though Allied <br />Universal Corporation is happy to respond to questions regarding safe handling of Allied's products, safe handling and use remains the <br />responsibility of the product's consumers and /or customers. No warranty of merchantability or fitness for purpose, or any other kind, express <br />or implied, is made regarding performance, stability or otherwise. Allied Universal Corp. will not be liable for any damages, losses, injuries or <br />consequential damages that may result from the use of or reliance on any information contained herein. No suggestions for use are intended <br />as, and nothing herein shall be construed as a recommendation to infringe any existing patents or violate any federal, state or local laws, rules, <br />regulations or ordinances. <br />