Laserfiche WebLink
For Task 104, plug and seal, shallow alluvial wells would not require a drill rig to <br />adequately seal these shallow wells. This would apply to wells with the prefix MW, <br />PAW, RW, SW, and two alluvial wells permitted by MR -116. <br />For Task 100, seal portals and vent shafts, portal dimensions were field measured and <br />vary slightly from permitted dimensions. The three Bates portals measure 9 feet tall by <br />18 feet wide. The West portal measures 8 feet tall by 14 feet wide. <br />Section 3.0 TR -68 9/29/2014 <br />