Laserfiche WebLink
,AMINING <br />C I�EM /�AL..S <br />10 v.rrnr(wal rPn;tuvtCwvf l CP <br />Orforn® D8 Depressant <br />What are Chevron Phillips Chemical OrfomO Mining Depressants? <br />Orfom® D8 Depressant (di- Sodium Carboxymethyl- tri- thiocarbonate) is a water soluble product useful for selective <br />depression of various mineral sulfides during the flotation process of chalcocite, molybdenite and other sulfide ores. This <br />product is most effective in depressing iron as Pyrite and chalcopyrite, and lead as galena, in primary and by- product <br />molybdenite flotation circuits. <br />BENEFITS <br />Orfom® D8 Depressant is offered as a 38- percent <br />aqueous solution to maximize safety and minimize <br />handling issues associated with alternative reagent <br />preparation. This product is very effective in <br />depressing iron and lead minerals when added to <br />the secondary grinding stage or cleaner circuit. The <br />Orfom® D8 is effective in basic and acid pH ranges. <br />It is also used in addition to Nokes reagent to reduce <br />its total dosage rate. The Orfom® D8 Depressant is <br />also less odorous than sodium hydrosulfide and <br />Nokes, and less toxic than other <br />traditional depressants. <br />APPLICATION GUIDELINES <br />OrfomO D8 Depressant dosage should be 5 g /ton (0.01lb /ton) to 25 g /ton (0.05 lb/ton) when added to the grinding mills <br />or conditioner. In the cleaner circuits, the dosage rates should be increased to 25 g /ton (0.05 lb/ton) to 500 g /ton (1 <br />lb/ton) of concentrate to make final grade. <br />Product Safety Information <br />Material Safety Data sheets are available upon request and on our website at http.// www .cpchem.com/specialtychemicals. <br />Before using this product the user is advised and cautioned to make its own determination and assessment of the safety and suitability of the product for the product for the specific use in question and is further advised against relying on the <br />information contained herein as it may relate to any specific use or application. It is the ultimate responsibility of the user to ensure that the product is suited and the information is applicable to the users specific application. Chevron Phillips <br />Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability or fitness for a particular purpose, regardless of whether oral or written, express or implied, or allegedly adsing from any usage of <br />any trade or from any course of dealing in connection with the use of the information contained herein or the product itself. The user expressly assumes all risk and liability, whether based in contract tort or otherwise, in connection with the use of the <br />information contained herein or the product itself. Further, information contained herein is given without reference to any intellectual property issues, as well as federal, state or local laws which maybe encountered in the use thereof. Such questions <br />should be investigated by the user. <br />Characteristics <br />Units <br />Cirfom® <br />D8 <br />ASTM <br />Method <br />Specific Gravity at 77 OF <br />g /cc <br />1.29 <br />D1298 <br />Density Conversion <br />lb/gal <br />10.8 <br />D1298 <br />Flash Point (PMCC) <br />cF <br />165 <br />D93 <br />Assay <br />% <br />38 <br />pH <br />13.2 <br />Pour Point ( °C) <br />OF <br />30 <br />D97 <br />Color <br />Orange /Red <br />Appearance <br />Solubility in Water <br />Complete <br />Appearance <br />Viscosity <br />77 OF <br />32 OF <br />cSt <br />7 <br />24 <br />D7042 <br />APPLICATION GUIDELINES <br />OrfomO D8 Depressant dosage should be 5 g /ton (0.01lb /ton) to 25 g /ton (0.05 lb/ton) when added to the grinding mills <br />or conditioner. In the cleaner circuits, the dosage rates should be increased to 25 g /ton (0.05 lb/ton) to 500 g /ton (1 <br />lb/ton) of concentrate to make final grade. <br />Product Safety Information <br />Material Safety Data sheets are available upon request and on our website at http.// www .cpchem.com/specialtychemicals. <br />Before using this product the user is advised and cautioned to make its own determination and assessment of the safety and suitability of the product for the product for the specific use in question and is further advised against relying on the <br />information contained herein as it may relate to any specific use or application. It is the ultimate responsibility of the user to ensure that the product is suited and the information is applicable to the users specific application. Chevron Phillips <br />Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability or fitness for a particular purpose, regardless of whether oral or written, express or implied, or allegedly adsing from any usage of <br />any trade or from any course of dealing in connection with the use of the information contained herein or the product itself. The user expressly assumes all risk and liability, whether based in contract tort or otherwise, in connection with the use of the <br />information contained herein or the product itself. Further, information contained herein is given without reference to any intellectual property issues, as well as federal, state or local laws which maybe encountered in the use thereof. Such questions <br />should be investigated by the user. <br />