Susan Burgmaier - 3 - January 19, 2015 <br />list the initial drilled diameter. Attached is a copy of each well abandonment report for the holes listed above. A <br />few discrepancies in the diameters were identified on the following holes: GVB -D6 -A (5.5/12), GVB -B2 -B <br />(9.625/6.6/16), GVB -B5 -A (9.625/7.6/ 16), GVB -B3 -C (10.75/7.6/16) <br />GVB -D -9B is aka GVB -D -9A because the coordinates for GVB -D -9A on the well abandonment report match the <br />location of GVB -D -9B. GVB -D -9A and GVB -D -9B were both permitted. I would like to leave the unsealed GVB -D- <br />9A with 6" casing on the list since there is apparently a missing abandonment report. <br />9. The December 27, 2006 Abandonment Report lists holes I13-66 and IP -66A. We cannot find a listing for <br />these holes on pages 2.05 -45i through 2.05 -45x. Please include holes IP -66 and IP -66A on the table on pages <br />2.05 -45i through 2.05 -45x or explain why the holes should not be listed. <br />BRL - DH -66 and DH -66A are listed on pages 2.05 -45ii and 2.05 -45x. These holes are also known as I13-66 and 113- <br />66A. An AKA was added to pages 2.05 -45ii and 2.05 -45x. <br />Additional Item: <br />Issue #16 in the DRMS' midterm review document MT -4 requested o plan, in accordance with Rule 2.05.3(8), for <br />the disposal of oll refuse that will be generated through the current permit term. The narrative on pages 2.05 -62 <br />and 2.05 -63 should address this issue. <br />Sincerely, <br />J. E. Stove <br />J. E. Stover, P.E. <br />Consulting Engineer <br />Revised Pages: <br />Volume I: 2.05 -45i thru 45x, 62 and 63 <br />Twenty -six (26) Well abandonment reports, not intended to be incorporated into permit <br />