Laserfiche WebLink
1 <br /> ADZ Laboratories, Inc. Inorganic Extended <br /> ' 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Golder Associates ACZ Project ID: L21518 <br /> IACZ ID WORKNUM PARAMETER METHOD QUAL DESCRIPTION <br /> L21518-05 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> I <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> I accurate evaluation(<10x MDL). <br /> L21518-06 WG374856 Manganese,dissolved M200.7 ICP D1 Sample required dilution due to matrix. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I WG374979 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L21518-07 WG374856 Potassium,dissolved M200.7 ICP D1 Sample required dilution due to matrix. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> I <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374979 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L21518-08 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> I concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> I concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I L21518-09 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> I calibration range. <br /> RA <br /> M300.0-Ion Chromatography Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I <br /> REPAD.15.06.05.01 <br /> 1 L21518-1412031346 Page 19 of 24 <br />