My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01-14_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2015-01-14_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:56:36 PM
Creation date
1/15/2015 8:43:58 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
Hydrology
Doc Date
1/14/2015
Doc Name
Fourth Quarter 2014 Groundwater Sampling at the Boettcher Quarry.
From
Golder Associates
To
DRMS
Permit Index Doc Type
Hydrology Report
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> ADZ Laboratories, Inc. Inorganic Extended <br /> ' 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Golder Associates ACZ Project ID: L21518 <br /> IACZ ID WORKNUM PARAMETER METHOD QUAL DESCRIPTION <br /> L21518-05 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> I <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> I accurate evaluation(<10x MDL). <br /> L21518-06 WG374856 Manganese,dissolved M200.7 ICP D1 Sample required dilution due to matrix. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I WG374979 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L21518-07 WG374856 Potassium,dissolved M200.7 ICP D1 Sample required dilution due to matrix. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> I <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374979 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> L21518-08 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> I concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> I concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> WG374722 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I L21518-09 WG374769 Barium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Sodium,dissolved M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> WG374979 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> I calibration range. <br /> RA <br /> M300.0-Ion Chromatography Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> I <br /> REPAD.15.06.05.01 <br /> 1 L21518-1412031346 Page 19 of 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.