My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01-14_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2015-01-14_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:56:36 PM
Creation date
1/15/2015 8:43:58 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
Hydrology
Doc Date
1/14/2015
Doc Name
Fourth Quarter 2014 Groundwater Sampling at the Boettcher Quarry.
From
Golder Associates
To
DRMS
Permit Index Doc Type
Hydrology Report
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Case <br /> ACZ Laboratories, Inc. Narrative <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 <br /> Golder Associates November 25, 2014 <br /> Project ID: 140-0159 1 <br /> ACZ Project ID: L21518 <br /> Sample Receipt <br /> ACZ Laboratories, Inc. (ACZ)received 9 ground water samples from Golder Associates on November 12, 2014. The <br /> samples were received in good condition. Upon receipt, the sample custodian removed the samples from the cooler, <br /> inspected the contents, and logged the samples into ACZ's computerized Laboratory Information Management System <br /> (LIMS). The samples were assigned ACZ LIMS project number L21518. The custodian verified the sample information <br /> entered into the computer against the chain of custody(COC)forms and sample bottle labels. <br /> Holding Times <br /> Any analyses not performed within EPA recommended holding times have been qualified with an"H"flag. <br /> Sample Analysis <br /> These samples were analyzed for inorganic parameters. The individual methods are referenced on both, the ACZ invoice <br /> and the analytical reports. The extended qualifier reports may contain footnotes qualifying specific elements due to QC <br /> failures. In addition the following has been noted with this specific project: <br /> 1. Sample L21518-03 was a duplicate identification for MW-1 based on bottles received. The Chain of Custody identified a <br /> MW-3 but did not receive one marked as such. Client was going to look at the data and compare to historical to make a <br /> determination. <br /> I <br /> I <br /> I <br /> I <br /> I <br /> i <br /> 1 <br /> 1 <br /> I <br /> L2riSr-24).i'P2M.P146 Page 2 of 24 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.