My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-11-13_PERMIT FILE - C2010089A
DRMS
>
Day Forward
>
Permit File
>
Coal
>
C2010089
>
2014-11-13_PERMIT FILE - C2010089A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 10:12:51 AM
Creation date
12/17/2014 9:11:08 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C2010089A
IBM Index Class Name
PERMIT FILE
Doc Date
11/13/2014
Doc Name
ARCADIS Report on Sediment Control
Section_Exhibit Name
Appendix 2.05.3(4)-1
Media Type
D
Archive
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 1: Soil Textural Class and Size Distribution <br />Unit # <br />Textural Class <br />% Clay <br />% Silt <br />% Very <br />Fine Sand <br />% Fine- <br />Medium <br />Coarse <br />Sand <br />% Very <br />Coarse <br />Sand (or <br />coarser) <br />Unified <br />Classification <br />10 <br />Clay loam <br />30 <br />40 <br />10 <br />10 <br />10 <br />SM -SC <br />71 <br />Silty clay loam <br />35 <br />55 <br />5 <br />0 <br />5 <br />SM -SC <br />77 <br />Loam -clay loam <br />25 <br />30 <br />10 <br />15 <br />20 <br />GM /SM -SC <br />78 <br />Loam - cobbly clay loam <br />25 <br />25 <br />10 <br />15 <br />25 <br />GM /GC <br />81 <br />Loam -clay loam <br />25 <br />30 <br />10 <br />15 <br />20 <br />SM -SC <br />82 <br />Loam -clay loam <br />25 <br />30 <br />10 <br />15 <br />20 <br />SM -SC <br />88 <br />very cobbly clay or sandy loam <br />25 <br />20 <br />15 <br />20 <br />20 <br />Sw <br />The 25 -year 24 -hour precipitation event was used to size the emergency spillways, according to Rule <br />4.05.9(2)(c)(ii), in order to satisfy the regulation Rule 4.05.9(7)(d) which requires that the minimum elevation of the <br />top of the settled embankment shall be 1.0 foot above the water surface in the pond with the emergency spillway <br />flowing at design depth. <br />The SEDCAD program was used to design the sedimentation ponds. SEDCAD cannot directly model a pond with <br />a gated principal spillway. This is due to the fact that SEDCAD cannot calculate the sedimentology without <br />outflow. But the following 3 step simulation methodology addresses this issue. The methodology was <br />recommended by Professor Warner, the SEDCAD developer. The details of 3 steps are described for Pond NHN- <br />001 as an example: <br />1) Model the un -gated pond with the combination of principal and emergency spillways to determine the <br />sediment storage and elevation. <br />The first SEDCAD report in Appendix 2.05.3(4) -2 titled as "10 -Year 24 -hour Storm Event for Pond NHN- <br />001" is used to determine the following parameters in Table 3. <br />• Contribution area of 114.9 acres and <br />• Runoff Volume of 10.92 ac -ft from Structure Summary on page 4 <br />The Sediment Storage Volume and Sediment Storage Elevation are 0.77 ac -ft and 5676.02 ft, <br />respectively from the Structure Detail on page 6. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.