Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80467 <br />Fortune Revenue Silver Mines Inc ACZ Project ID: L21373 <br />AC2ID WORKNUM PARAMETER METHOD QUAl 'DESCRIPTION <br />L21373 -07 WG374098 Total Hot Plate Digestion <br />WG374349 <br />WG374096 Total Recoverable Digestion <br />WG374534 Antimony, total <br />Beryllium, total <br />Cadmium, total <br />Chromium, total <br />Copper, total <br />WG374424 Mercury, total <br />WG374534 Molybdenum, total <br />Selenium, total <br />WG374191 Silica, total <br />WG374534 Thallium, total <br />Uranium, total <br />WG374370 Chloride <br />WG374129 Conductivity @25C <br />pH <br />WG374080 Phosphorus, ortho dissolved <br />WG374054 Residue, Filterable (TDS) @180C <br />M200.2 ICP <br />M200.2 ICP -MS <br />M200.2 ICP <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M245.1 CVAA <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M200.7 ICP <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />SM4500CI -E <br />SM2510B <br />SM4500H+ B <br />M365.1 - Automated Ascorbic <br />Acid <br />M365.1 - Automated Ascorbic <br />Acid <br />M365.1 - Automated Ascorbic <br />Acid <br />M365.1 - Automated Ascorbic <br />Acid <br />SM2540C <br />WG374059 Residue, Non - Filterable (TSS) @105C SM2540D <br />WG374276 Total Alkalinity <br />REPAD.15.06.05.01 <br />SM2540D <br />SM2540D <br />SM2320B - Titration <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />ZS Digestion procedures have the potential to trigger silica <br />polymerization and precipitation, leading to low biased <br />results. Silica chemistry is complex and polymerization <br />kinetics are unpredictable. Dissolved and/or acid soluble <br />silica analyses may provide more accurate measurements. <br />DJ Sample dilution required due to insufficient sample. <br />DJ Sample dilution required due to insufficient sample. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />ZW Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content <br />ZW Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content <br />H3 Sample was received and analyzed past holding time. <br />QP The sample was filtered at the laboratory more than 15 <br />minutes after sample collection. For Orthophosphate, 40 <br />CFR Part 136.3 requires filtration within 15 minutes of <br />collection. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />ZU Analysis date/time preceeds filter date /time. A portion of <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />N1 See Case Narrative. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />ZW Method deviation. The sample was centrifuged prior to <br />analysis due to high solid content <br />L21373- 1411211444 Page 29 of 33 <br />