Laserfiche WebLink
Table No. 2 Applegate <br /> Bucklen Equipment Company, Inc. <br /> Bucklen Pit(M-1982-131) rr�O* Group, Inc. <br /> Operational Consumptive Use (aka Operation CU) Date Revised: 9/12/2014 <br /> From Mining AG Job#: 08-127 <br /> Month Percent of Monthly Water Retained Water Used Operation <br /> Annual Production in Product for Dust Control CU <br /> Production [tons] [ac-ft] [ac-ft] [ac-ft] <br /> (A) (B) (C) (D) (E) <br /> November 7% 14,000 0.21 0.00 0.21 <br /> December 6% 12,000 0.18 0.00 0.18 <br /> January 9% 18,000 0.26 0.00 0.26 <br /> February 5% 10,000 0.15 0.00 0.15 <br /> March 6% 12,000 0.18 0.57 0.75 <br /> April 10% 20,000 0.29 0.55 0.85 <br /> May 12% 24,000 0.35 0.57 0.92 <br /> June 8% 16,000 0.24 0.55 0.79 <br /> July 10% 20,000 0.29 0.57 0.87 <br /> August 14% 28,000 0.41 0.57 0.98 <br /> September 6% 12,000 0.18 0.55 0.73 <br /> October 7% 14,000 0.21 0.57 0.78 <br /> Total 100% 200,000 2.94 4.51 7.45 <br /> Total Annual Production= 200,000 tons <br /> Moisture Content of Product= 2% by weight <br /> Water Used for Dust Control= 6,000 gallons per day during March through October <br /> Notes: <br /> (A)Estimated monthly production percentages. Provided by Bucklen Equipment Company <br /> (B)Monthly Production=(Total Annual Production)*(A) <br /> (C)Water Retained in Product=[(Moisture Content of Product)*(B)*20001/(62.4*43560) <br /> (D)Water Used for Dust Control is estimated to be 6000 gallons per day during March through October <br /> (E)Operation CU=(C)+(D) <br /> N:\08127 Bucklen Pit Augmentation\Disciplines (Tech nical)\Water Rights\SWSP\WY 2015\Bucklen Pit 2015.xlsx <br />