Laserfiche WebLink
June 2014 1400159 <br /> Table 1: Proposed Analyte List-Groundwater Monitoring Wells MWA through MW-7 <br /> Parameter Recommended Method PQL/Reporting Limit <br /> (mg/L) Unless Noted <br /> Metals <br /> Barium, Dissolved EPA M200.7 0.02 <br /> Boron, Dissolved EPA M200.7 0.05 <br /> Iron, Dissolved EPA M200.7 0.05 <br /> Man anese Dissolved EPA M200.7 0.03 <br /> Ma'or Ions and Water Quality Parameters <br /> pH 150.1 0.1 (S.U.) <br /> Total Dissolved Solids filterable residue EPA M160.1 /SM2540C 20 <br /> Alkalinity SM 2320 B Titrimetric 2 <br /> Calcium, Dissolved EPA M200.7 1 <br /> Chloride EPA M300.1 1 <br /> Ma nesium, Dissolved EPA M200.7 1 <br /> Potassium, Dissolved EPA M200.7 2 <br /> Sodium, Dissolved EPA M200.7 2 <br /> Sulfate EPA M300.1 1 <br /> Note: Proposed analyte list to be effective starting third quarter 2014. <br /> Golder <br /> I:\14\1400159\0110\ChangesAnalyListGWSamplingBoettcher_Fnl-17Jun14\Table 1.xlsx\Table 1- Associates <br />