A CZ Laboratories, Inc. • , : • - - <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 A * • <br /> Star Mine Operations LLC ACZ Project ID: L18297 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> L18297-01 WG364392 Aluminum,total M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Iron,total M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Manganese,total M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> Silica,total M200.7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> M200.7 ICP IRS RPD of matrix spikes for total or total recoverable silica is <br /> outside acceptance limits. Acceptable precision for other <br /> metals indicates silica RPD failure may be attributed to <br /> digestion-triggered silica polymerization and precipitation. <br /> M200.7 ICP ZS Digestion procedures have the potential to trigger silica <br /> polymerization and precipitation,leading to low biased <br /> results. Silica chemistry is complex and polymerization <br /> kinetics are unpredictable. Dissolved and/or acid soluble <br /> silica analyses may provide more accurate measurements. <br /> WG364502 Chloride SM4500CI-E M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG364640 Cyanide,total M335.4-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG364641 Cyanide,WAD SM4500-CN I-Colorimetric w/ RA Relative Percent Difference(RPD)was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation(<1Ox MDL). <br /> WG364272 Fluoride SM450OF-C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG364143 Phosphorus,ortho dissolved M365.1-Automated Ascorbic QP The sample was filtered at the laboratory more than 15 <br /> Acid minutes after sample collection. For Orthophosphate,40 <br /> CFR Part 136.3 requires filtration within 15 minutes of <br /> collection. <br /> M365.1-Automated Ascorbic RA Relative Percent Difference(RPD)was not used for data <br /> Acid validation because the sample concentration is too low for <br /> accurate evaluation(<10x MDL). <br /> M365.1-Automated Ascorbic ZU Analysis date/time preceeds filter date/time. A portion of <br /> Acid sample was filtered and analyzed prior to the creation of a <br /> Filter workgroup. <br /> WG364338 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation(<1 Ox MDL). <br /> WG364620 Sulfate D516-02-Turbidimetric M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level.The recovery of the associated control sample(LCS <br /> or LFB)was acceptable. <br /> REPAD.15.06.05.01 <br /> L18297-1406020932 Page 26 of 32 <br />