Laserfiche WebLink
TABLE 3 <br /> EXTERNAL POND EARTHWORKS CQA TEST SUMMARY AND <br /> TESTING FREQUENCY <br /> Leak Pipe Soil <br /> Structural Detection Bedding Base, Liner <br /> Material Quantity/ 'Fill, Fill"" Material Coarse Fill <br /> Number of Tests and Test Fre uenc (SF) (LDF) "(PB (BIC) (SL <br /> Quantity of Material Placed(CY) 57,775 25 20 130 6,075 <br /> Sieve Tests Performed 4 2 1 1 2 <br /> Specified Sieve Test Frequency 50,000 10,000 10,000 NA 5,000 <br /> Actual Sieve Test Frequency 14,444 25 20 130 3,038 <br /> Atterberg Limit Tests Performed 4 2 1 1 2 <br /> Specified Atterberg Limit Test Frequency 50,000 10,000 10,000 NA 5,000 <br /> Actual Atterberg Limit Test Frequency 14,444 13 20 130 3,038 <br /> Proctor Compaction Tests Performed 29(Note 3) NA 0 0 2 <br /> S ecified Compaction Test Frequency 50,000 NA NA NA 5,000 <br /> Actual Compaction Test Frequency Note 3 NA NA NA 3,038 <br /> Permeability Tests Performed NA NA NA NA 2 <br /> Specified Permeability Test Frequency NA NA NA NA 5,000 <br /> Actual Permeability Test Frequency NA NA NA 3,038 <br /> %Moisture tests Performed 33 2 1 1 26 <br /> Specified%Moisture Test Frequency 2,000 10,000 10,000 NA 500 <br /> Actual%Moisture Test Frequency N/A 13 20 NA 234 <br /> Field Density Tests Performed N/A N/A 0 0 24 <br /> ,Specified Field Density Test Frequency 2,000 NA NA NA 500 <br /> Actual Field Density Test Frequency N/A NA NA NA 253 <br /> Notes: <br /> 1. Test Frequencies are in cubic yards. <br /> 2. NA=Not Applicable. <br /> 3. A portion of the Structural Fill placed was not Proctor-testable due to amount of oversize(+3/4")material in accordance with ASTM 1557. <br /> 4. NP=Non Plastic <br /> October 2001 Golder Associates 003-2182.4 <br /> I/00/2182/Tables/2182T03 As <br />