Laserfiche WebLink
LOB FIELD DENSITY AND MOISTURE CONTENT TEST SUMMARY <br /> SOIL LINER FILL <br /> Test Date Location, Northing Easting Elevation Nuclear Oven Dry Max. Optimum Percent Moisture Pass/ <br /> No. Wet Moisture Density Dry Moisture Compaction Content Pao <br /> Density Content Density Content Over <br /> (ft) (ft) (ft) (lbs/ft) (%) (lbs/ft) (lbs/ft) (%) Optimum <br /> LOB-SLN-1 10/22/99 SOIL LINER 51,099.9 36,667.2 9,561.9 128.3 13.1 113.4 117.0 13.5 97 -0.4 P <br /> LOB-SLN-2 10/22/99 1 SOIL LINER 51,076.2 136,665.1 1 9,558.0 1 126.1 14.5 1 110.1 1 112.0 1 15.0 98 -0.5 P <br /> January 20W <br /> 1199/2011/1260/Slfiwke xis Golder Associates 993-2011 <br />