Laserfiche WebLink
Phase I Low Volume Solution Collection (readings in ft) <br />Pond Lvl / XDCR #1 System Press / XDCR #2 <br />57.30 45.40 <br />Phase I Pond Piezometers (readings in ft) <br />Piezo #1 (HAND) Piezo #2 (AUTO) <br />0.51 0.69 <br />Phase II & III High Volume Solution Collection (readings in ft) <br />Pump / XDCR #4 Pump / XDCR #5 <br />29.6 29.2 <br />Phase II & III Low Volume Solution Collection (readings in ft) <br />Pump/ XDCR #1 (AUTO) Pump/ XDCR #2 (AUTO) <br />0.38 0.32 <br />Phase II & III Pond Piezometer (readings in ft) <br />Piezo (Pipe) <br />36.50 <br />Phase IV High Volume Solution Collection (readings in ft) <br />Pump #4 / XDCR #307 Pump #5 / XDCR #308 <br />42.2 41.9 <br />Phase IV Low Volume Solution Collection (readings in inches) <br />Pump / XDCR #1 Pump / XDCR #2 <br />18.50 13.10 <br />Phase V High Volume Solution Collection (readings in ft) <br />XDCR #311 (AUTO) XDCR #312 (AUTO) <br />27.00 27.09 <br />Phase V Low Volume Solution Collection (readings in inches) <br />XDCR #001 XDCR #002 <br />11.38 17.00 <br />External Pond Low Volume Solution Collection (readings in inches) <br />Pump / XDCR #1 -EXT (AUTO) Pump / XDCR #2 -EXT (AUTO) <br />13.4 15.0 <br />PERMIT #: M- 1980 -244 <br />INSPECTOR'S INITIALS: TCI <br />INSPECTION DATE: September 4, 2013 <br />Pump / XDCR #6 <br />33.1 <br />Pump #6 / XDCR #309 <br />41.7 <br />XDCR #313 (AUTO) <br />27.04 <br />XDCR pipe ( #310 <br />Reserved <br />41.8 <br />XDCR #314 (AUTO) <br />27.45 <br />Page 3 of 8 <br />