SCHEMATIC OF UNTESTED <br />SPECIMEN <br />WELD B WELD A <br />TOP SHEET <br />— BOTTOM SHEET <br />DIRECTION OF INITIAL PEEL <br />LOCUS -OF <br />TYPES OF BREAKS BREAK CODE <br />a. FTB = FILM TEAR BOND <br />BREAK <br />DESCRIPTION CLASSIFICATIONS <br />AD ADHESION FAILURE NON -FTB <br />BRK EITHER IN TOP OR OTTOM SHE T. BE IN FTB <br />BREAK IN OUTER EDGE OF SEAM. BREAK FTB <br />SE1 CAN BE IN EITHER TOP OR BOTTOM <br />SE2 <br />AD -BRK <br />BREAK AT INNER EDGE OF SEAM THROUGH FTB <br />BOTH SHEETS. <br />BREAK IN FIRST SEAM AFTER SOME <br />ADHESION FAILURE. BREAK CAN BE IN <br />EITHER THE TOP OR BOTTOM SHEET. <br />NOT TO SCALE <br />FTB <br />GOLD MINING COMPANY <br />IGJECT <br />PSES PIPE RACK LINER EXTENSION <br />Iu <br />DESTRUCTIVE SAMPLE TEST CODES FOR <br />DUAL HOT WEDGE FUSION WELDS <br />DESIGNED BY I — CHECKED BY JNM DATE <br />a mec DRAWN BY ACW APPROVED BY JNM 12/3/12 <br />REV <br />i1I ACC FIGURE No, REV <br />FIGURE 3 3 0 <br />