Laserfiche WebLink
Cripple Creek & Victor Gold Mining Company <br />PSES Pipe Rack Liner Extension <br />Final Report <br />Quality uality Assurance Monitoring &Test Results <br />February 4, 2014 <br />4.1.3 Atterberg Limits <br />AMEC performed Atterberg limits testing of the DCF materials. Samples tested met <br />project specifications for Atterberg limits. Atterberg limits test data are presented in <br />Appendix H and summarized in Table 4. <br />AMEC performed five CQA Atterberg limits tests of DCF. The testing frequency <br />(approximately one test per 881 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 1,000 cubic yards. The DCF Atterberg limits met project <br />specifications, and the results are presented in Appendix H and summarized in <br />Table 4. <br />4.2 Field Testing and Monitoring <br />AMEC observed earthwork fill operations at the PSES Pipe Rack Liner Extension to <br />verify, when necessary; lift thickness, adequate compaction, and acceptable moisture <br />conditions. <br />4.2.1 Random Fill Subgrade Preparation <br />AMEC monitored random fill subgrade preparation for compliance with the Technical <br />Specifications. It was verified that Ames removed protruding rocks from the subgrade <br />surface and the subgrade surface was smooth and unyielding prior to GCL placement. <br />4.2.2 Drain Cover Fill <br />AMEC provided visual monitoring of DCF placement. One AMEC monitor and one <br />Ames labourer per machine monitored the DCF placement, unless two machines were <br />within approximately 50 feet of each other during DCF placement. Where present, <br />AMEC verified that wrinkles in the geomembrane did not fold over. PVC grade <br />markers were placed on a maximum 50 foot by 50 foot grid and at grade breaks; and <br />all fill materials were suitable. AMEC continuously inspected geomembrane during <br />DCF placement; marked areas for repair if required; and verified that all repairs were <br />completed to project specifications. After final grading, AMEC monitored removal of <br />PVC grade markers. <br />9 <br />