DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Report
Doc Date
2/7/2014
Doc Name
Final Report QA Monitoring and testing volume 2 of 2 document 1 of 3Mill Site Earth works
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ameO <br /> C. Flowable fill shall be manufactured by a ready-mix concrete producer with a minimum of 1 year <br /> experience in the production of similar products. <br /> PART 2: PRODUCTS <br /> 2.01 MATERIALS <br /> A. Portland Cement,ASTM C 150,Type II. <br /> B. Coarse Aggregate, ASTM C 33, except that clay and shale particles shall not exceed I percent of <br /> total aggregate. <br /> C. Fine Aggregate,ASTM C 33,washed natural sand. <br /> D. Flowable Fill containing, at a minimum, cementitious materials and water. The mixture may also <br /> contain fine aggregate or filler, and/or chemical admixtures in any proportions such that the final <br /> product meets the strength, flow consistency and shrinkage requirements included in this <br /> specification,as approved by the CERTIFYING ENGINEER. <br /> 1. Portland Cement:ASTM C 150,Type II. <br /> 2. Mixing Water <br /> 3. Air-Entraining Admixture:ASTM C260. <br /> 4. Chemical Admixtures:ASTM C494. <br /> 5. Aggregate:ASTM C33. <br /> 2.02 MIXES <br /> A. Mix Designs: <br /> Concrete mix design shall be designed by an independent testing laboratory. <br /> B. Cast-In-Place Concrete: <br /> 1. Cast-in-place concrete with reinforcing steel shall have a minimum 28-day compressive <br /> strength of 4,000 psi. <br /> 2. Maximum Aggregate size of l-inch. <br /> 3. Placement slump between 2-inches and 5-inches. <br /> 4. Air entrainment of 5%to 8%. <br /> C. Flowable Fill: <br /> 1. Minimum strength of 300 psi,ASTM C 39,at 28 days after placement. <br /> Section 03300 Page 2 of 5 May 9,2012 <br /> Cast-In-Place Concrete Revision 1 <br />