Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Star Mine Operations LLC ACZ Project ID: L16199 <br />L16199.11 WG357502 Beryllium, dissolved M200.8 ICP -MS <br />MA <br />Recovery for either the spike or spike duplicate was outside <br />of the acceptance limits; the RPD was within the <br />acceptance limits. <br />WG357726 Copper, dissolved M200.8 ICP -MS <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG357326 Iron, dissolved M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Manganese, dissolved M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG357522 Silica, total M200.7 ICP <br />ZS <br />Digestion procedures have the potential to trigger silica <br />polymerization and precipitation, leading to low biased <br />results. Silica chemistry is complex and polymerization <br />kinetics are unpredictable. Dissolved and/or acid soluble <br />silica analyses may provide more accurate measurements. <br />WG357326 Zinc, dissolved M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG357541 Chloride SM4500CI -E <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG357353 Cyanide, total M335.4 - Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG357361 Cyanide, WAD SM4500 -CN I- Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG357415 Fluoride SM450OF -C <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG357006 Phosphorus, ortho dissolved M365.1 - Automated Ascorbic <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />Acid <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG357040 Residue, Non - Filterable (TSS) @105C SM2540D <br />Q1 <br />Sample integrity was not maintained. See Case Narrative. <br />SM2540D <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG357482 Sulfate D516 -02 - Turbidimetric <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />REPAD.15.06.05.01 <br />Page 74 of 79 <br />