My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-12-23_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2013-12-23_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:38:18 PM
Creation date
12/23/2013 4:53:02 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
12/23/2013
Doc Name
4th Quarter Groundwater Sampling
From
Golder Associates
To
DRMS
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i; <br />L� <br />t <br />1 <br />AUZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Golder Associates <br />ACZ Project ID: L15611 <br />ACZ ID WORKNUM PARAMETER <br />METHOD <br />QUAL <br />DESCRIPTION <br />L15611 -05 WG355271 Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355667 Fluoride <br />SM4500F -C <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />Zinc, dissolved <br />M200.7 ICP <br />D1 <br />associated control sample (LCS or LFB) was acceptable. <br />SM4500F -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355464 Residue, Filterable (TDS) @180C <br />SM2540C <br />H2 <br />Initial analysis within holding time. Reanalysis for the <br />WG355271 Chloride <br />M300.0 - Ion Chromatography <br />N1 <br />required dilution was past holding time. <br />SM2540C <br />HE <br />Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />WG355667 Fluoride <br />SM4500F -C <br />M2 <br />item C5 of ACZ's Terms & Conditions). <br />WG355271 Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />SM4500F -C <br />RA <br />calibration range. <br />L15611 -06 WG355330 Copper, dissolved <br />M200.7 ICP <br />D1 <br />Sample required dilution due to matrix. <br />Manganese, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Zinc, dissolved <br />M200.7 ICP <br />D1 <br />Sample required dilution due to matrix. <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG355271 Chloride <br />M300.0 - Ion Chromatography <br />N1 <br />See Case Narrative. <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355667 Fluoride <br />SM4500F -C <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />SM4500F -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355464 Residue, Filterable (TDS) @180C <br />SM2540C <br />H2 <br />Initial analysis within holding time. Reanalysis for the <br />required dilution was past holding time. <br />SM2540C <br />HE <br />Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />WG355271 Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />N1 <br />See Case Narrative. <br />L15611 -07 WG355271 Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355667 Fluoride <br />SM4500F -C <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />SM4500F -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG355464 Residue, Filterable (TDS) @180C <br />SM2540C <br />H2 <br />Initial analysis within holding time. Reanalysis for the <br />required dilution was past holding time. <br />WG355271 Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non- target analyte exceeded <br />calibration range. <br />REPAD.15.06.05.01 <br />IPage 21 of 26 <br />
The URL can be used to link to this page