Laserfiche WebLink
• SPILLWAYS BETWEEN T-2 AND OUTFACE 001 6/6 <br />Two 4 inch emergency spillway pipes have adegate capacity to <br />handle the design flow of 70 gpm. One 6 inch diamter <br />primary spillway has the capacity to handle the design flow. <br />If the 25-year event occured, the maximum flow expected from <br />the long pond would be the maximum capacity from one G-inch <br />primary spillway and two four inch diameter emergency <br />spillways. Since the long pond and pond T-2 have identical <br />spillway configurations, the 25-year event will be decanted in <br />the same manner from both ponds. <br />The primary spillway will be a six inch diameter pipe. The <br />emergency spillway will be two four inch diameter pipes. <br />The calculations and information presented on the preceeding <br />pages, P-9-5 through P-9-10, was prepared by me during the <br />month of er 1992 and revised August and September 1995, <br />and th~~~,tA~'• ~t,~ presented is true and correct to the best of <br />my kn~e~g~.~lief. <br />~*: mes; ~ Stover Date <br />;~:~ P. E.~ ~1~. 19230 <br />• +~• <br />.9 . ~ <br />• .~ <br />• ~..~ ~. <br />~~FS •......• G i~ <br />~:~OHAL ~~i~ <br />• ...• <br />• P-9-10 <br />09-27-95 <br />