Laserfiche WebLink
Leadville Mill -10 year Storm -� <br />Rating Table for Triangular Channel <br />Project Description <br />Project File c:\ haestad \academiclfmw\projectl.fm2 <br />Worksheet Union Milling - Leadville Mill <br />Flow Element Triangular Channel <br />Method Manning's Formula <br />Solve For Discharge <br />Constant Data <br />Mannings Coefficient 0.035 <br />Channel Slope 0.050000 ft /ft <br />Left Side Slope 1.000000 H: V <br />Right Side Slope 1.000000 H: V <br />Input Data <br />Minimum Maximum Increment <br />Depth 0.00 0.45 0.05 ft <br />Rating Table <br />Depth Discharge Velocity <br />(ft) (cfs) (ft/s) <br />0.00 <br />0.00 <br />0.00 <br />0.05 <br />0.16e -2 <br />0.64 <br />0.10 <br />0.01 <br />1.02 <br />0.15 <br />0.03 <br />1.34 <br />0.20 <br />0.06 <br />1.62 <br />0.25 <br />0.12 <br />1.88 <br />0.30 <br />0.19 <br />2.13 <br />0.35 <br />0.29 <br />2.36 <br />0.40 <br />0.41 <br />2.58 <br />0.45 <br />0.56 <br />2.79 <br />12/13/12 Academic Edition FlowMaster v5.17 <br />01:25:23 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755 -1666 Page 1 of 1 <br />