My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-11-08_REPORT - M1977342
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1977342
>
2013-11-08_REPORT - M1977342
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:37:11 PM
Creation date
11/8/2013 2:46:08 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977342
IBM Index Class Name
REPORT
Doc Date
11/8/2013
Doc Name
Copy of CDPHE 5 day spill report as required by Section 3.1.13 of the Hard Rock Mining Regulations
From
Henderson Mine
To
DRMS
Email Name
PSH
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br />i <br />001929 -No. 1 Diesel Fuel y <br />Date of Issue: 20- Mar -2007 <br />Page 3/8 <br />Status: Final <br />Environmental precautions: Prevent spilled material from entering sewers, storm drains, other unauthorized drainage systems, and <br />natural waterways. Dike far ahead of spill for later recovery or disposal. Use foam on spills to minimize vapors (see Section 5). <br />Spilled material may be absorbed into an appropriate absorbent material. <br />Methods for cleaning up: Notify fire authorities and appropriate federal, state, and local agencies. Immediate cleanup of any spill is <br />recommended. If spill of any amount is made into or upon navigable waters, the contiguous zone, or adjoining, shorelines, notify the <br />National Response Center (phone number 800- 424 - 8802). <br />DLlf��a.:: AN�3:.$ TC���E :...:...::.:......:.....::.:::::.:..::. ::....�........................ :. :......- ..... ... .. . <br />Handling: Open container slowly to relieve any pressure. Bond and ground all equipmentwhen transferring from one vessel to another. <br />Can accumulate static charge by flow or agitation. Can be ignited by static discharge. The use of explosion -proof electrical equipment <br />is recommended and maybe required (see appropriate fire codes). Refer to NFPA -704 and /or API RP 2003 for speck <br />bonding /grounding requirements. Do not enter confined spaces such as tanks or pits without following proper entry procedures such as <br />ASTM D -4276 and 29CFR 1910.146. The use of appropriate respiratory protection is advised when concentrations exceed any <br />established exposure limits (see Section 8). <br />Do not wear contaminated clothing or shoes. Keep contaminated clothing away from sources of ignition such as sparks or open flames. <br />Use good personal hygiene practices. <br />"Empty" containers retain residue and may be dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such <br />containers to heat, flame, sparks, or other sources of ignition. They may explode and cause injury or death. "Empty" drums should be <br />completely drained, properly bunged, and promptly shipped to the supplier or a drum reconditioner. All containers should be disposed <br />of in an environmentally safe manner and in accordance with governmental regulations. <br />Before working on or in tanks which contain or have contained this material, refer to OSHA regulations, ANSI Z49.1, and other <br />references pertaining to cleaning, repairing, welding, or other contemplated operations. <br />Storage: Keep container(s) tightly closed. Use and store this material in cool, dry, well- ventilated areas away from heat, direct <br />sunlight, hot metal surfaces, and all sources of ignition. Post area "No Smoking or Open Flame." Store only in approved containers. <br />X0vsu��Gar��+��.s <br />ggni;.. <br />:. ;: •.::....:::. <br />e <br />ydrodesulfurized Kerosene <br />TWA: 200 mg /m' <br />— <br />�- <br />.C9 -16 <br />Skin <br />ydrotreated Distillate, Light <br />TWA: 200 mg /m' <br />--- <br />- -- <br />.C9 -16 <br />Skin <br />based on Kerosene <br />8008 -20 -6 <br />erosene ..C9 -16 <br />TWA: 200 mg /m' <br />- -- <br />- -- <br />r <br />Skin <br />Note: State, local or other agencies or advisory groups may have established more stringent limits. Consult an industrial hygienist or <br />similar professional, or your local agencies, for further information. <br />Engineering controls: If current ventilation practices are not adequate to maintain airborne concentrations below the established <br />exposure limits additional engineering controls may be required. <br />Personal Protective Equipment (PPE): <br />Eye /Face: Approved eye protection to safeguard against potential eye contact, irritation, or injury is recommended. Depending <br />on conditions of use, a face shield may be necessary. <br />Skin: The use of nitrile gloves impervious to the specific material handled is advised to prevent skin contact, possible irritation, <br />and skin damage (see glove manufacturer literature for information on permeability). Depending on conditions of use, nitrile <br />apron and /or arm covers may be necessary. <br />
The URL can be used to link to this page
Your browser does not support the video tag.