Laserfiche WebLink
Mineral Joe Mine — Drainage Design Plan 47 <br />Attachment 1. Rip Rap Granular Bedding Specifications (from UDFCD 2011) <br />DRAINAGE CRITERIA MANUAL (V 1) MAJOR DRAINAGE <br />Table MDA I—Gradation for Granular SWiding <br />U S. Standard Sieve Sao <br />Percent Weight by Pass' <br />Square -Mesh Slaves <br />Type I CDOT Sw, 703,01 <br />Type 11 CDOT Sw, <br />703,09 Class A <br />3 inches <br />Type 11 <br />90-100 <br />1% inches <br />4 <br />— <br />11/4 inoes <br />— <br />20-90 <br />inches <br />100 <br />----- <br />#4 <br />95-100 <br />0-20 <br />#16 <br />45-80 <br />#50 <br />10-30 <br />#100 <br />2.10 <br />#200 <br />0-2 <br />The Type I and Type II bedding specifications shown in Table MD -11 were developed using the T-V filter <br />criteria and the fact that bedding which will protect an underlying non-cohesive soil with a mean grain size <br />of 0.045 mm will protect anything finer. Since the T-V fitter criterion provides some latitude in establishing <br />bedding gradations, it is possible to make the Type I and Type 11 bedding specifications conform with <br />Colorado Division of Highways' aggregate specifications The Type I bedding in Table MD-11 is designed <br />to be the lower layer in a two-layer filter for protecting fine-grained soils and has a gradation identical to <br />Colorado Department of Transportation's (CDO'rs) concrete sand specification AASHTO M-6 (CDOT <br />Section 703.01). Type 11 bedding, the upper layer in a two-layer filter, is equivalent to Colorado Division <br />of Highways! Class A filter material (Section 703,09 Class A) except that it permits a slightly larger <br />maximum rock fraction When the chary* is excavated in coarse sand and gravel (50% or more of <br />coarse sand and gravel retained on the #40 sieve by weight), only the Type It filter is required. <br />Otherwise, a two-layer bedding (Type I topped by Type 11) is required. Alternatively, a single 12-inch layer <br />of Type 11 bedding can be used, except at drop structures For required bedding thickness, see Table <br />MD -12, At drop structures, a combination of filter fabnc and Type 11 bedding is acceptabile as an <br />alternative to a two-layer fitter <br />Table MD-12—Thicknesils Requirements, for Granular Bedding <br />Riprap Designation <br />g ess (inches) <br />g Thi <br />Minimum Bedding Thickness g <br />Fine-Grained Soils' <br />Coarse-Grained Solis— <br />Type I <br />Type 11 <br />Type 11 <br />VL (dw = 6 in), L (dw = 9 in) <br />4 <br />4 <br />M (dw = 12 in) <br />4 <br />4 <br />H (4dso = 18 in) <br />4 <br />6 <br />(d.= 24 in) <br />4 <br />6 <br />May substitute one 12-inch layer of Type 11 bedding. The substitution of one layer of Type 11 bedding shall not <br />be permitted at drop structures, The use of a con-bnation of idler fabric and Type 11 bedding at drop structures <br />is acceptabic <br />Fifty percent or mare by weight retained on the # 40 sieve <br />Rev 042008 <br />Urban Drainage and Flood Contlof Distract <br />URI% <br />4148B.131029 Whetstone Associates 4 <br />