JD-6 Mine – Drainage Design Plan 47 <br />Attachment 1. Rip Rap Granular Bedding Specifications (from UDFCD 2011) <br />DRAINAGE CRITERIA MANUAL (V 1) MAJOR DRAINAGE <br />Table MD -1 I-- Gradation for Granular Bedding <br />U.S. Standard Sieve Size <br />Percent Weight by Pass Square-Mesh Sieves <br />Type I COOT Sect 703 01 <br />Type it CDOT SW, <br />703,09 Class A <br />3 inches <br />9t3 100 <br />inches <br />inches <br />— <br />20-90 <br />- - - --------- - 1/i, Inches <br />100 <br />#4 <br />95-100 <br />0-20 <br />#16 <br />45-80 <br />— <br />#50 <br />10.30 <br />#100 <br />2.10 <br />— <br />#200 <br />0_2 <br />0-3 <br />The Type I and Type 11 bedding specifications shown In Table MD -11 were developed using the T-V filter <br />criteria and the fact that bedding which will protect an underlying non - cohesive soil with a mean grain size <br />of 0,046 mm Will protect anything finer. Since the T-V filter criterion provides some latitude in establishing <br />bedding gradations, it is possible to make the Type I and Type 11 bedding specifications conform with <br />Colorado Division of Highways' aggregate specifications The Type I bedding in Table MD-11 is designed <br />to be the lower layer in a two-layer filter for protecting fine-grained soils and has a gradation identical to <br />Colorado Department of Transportation's (CDO'rs) concrete send specification AASHTO M-6 (CDOT <br />Section 703,01), Type 11 bedding, the upper layer in a two-layer fitter, is equivalent to Colorado Division <br />of Highways' Class A filter material (Section 703.09 Class A) except that it permits a slightly larger <br />maximum rock fraction When the channal is excavated in coarse sand and gravel (50% or more of <br />coarse sand and gravel retained on the #40 sieve by weight), only the Type 11 filter Is required <br />Otherwise. a two-layer bedding (Type I topped by Type 11) is required. Alternatively, a single 12-inch layer <br />of Type 11 bedding can be used, except at drop structures. For required bedding thickness, see Table <br />MD -12. At drop structures, a combination of fitter fabric and Type 11 bedding is acceptable as an <br />alternative to a two-layer fitter, <br />Table MD-12—Thickness Requirements for Granular Bedding <br />Minimum Bedding Thickness (inches) <br />Riprap Designation Fine-Grained Soils" Coarse-Gr;ihSoilT <br />Type I Type 11 Type Ii <br />VL ( dw = 6 in), L Pao = 9 in) 4 4 6 <br />M (dw = 12 in) 4 4 6 <br />H (d5o = 18 in) 4 6 8 <br />VH (car = 24 in) 4 6 <br />May substitute one 12-inch layer of Type 11 bedding. The substitution of one layer of Type 11 bedding shall not <br />be permitted at drop structures The use of a combination of filter fabric and Type 11 bedding at drop structures <br />is acceptable. <br />Fifty percent or crone by weight retained on the # 40 sieve. <br />Rev 0412008 <br />Urban Drainage and Rood Cont'ol Dotict <br />MD-87 <br />4148A.131028 Whetstone Associates 6 <br />