Colowyo Coal Company, L.P. <br />Attn.: Mr. Juan Garcia <br />January 4, 2013 <br />Page 3 of 7 <br />SHANNON 6WILSON, INC. <br />Spoil. In our previous analysis of South Taylor spoil fills (Shannon & Wilson, 2006) we <br />used a shear strength of 30 degrees friction and no cohesion for the spoil. This is a low <br />bound strength that the Division of Mining, Reclamation, and Safety has requested to be <br />considered in previous spoil stability analyses for permanent excess spoil at the site. <br />Subsequently, large scale, direct shear testing was performed on five samples of spoil; <br />results are summarized on Figure 10. The results of the testing indicated a mean value of <br />35 degrees and cohesion of 750 pounds per square foot (psf). The spoil exhibits an angle <br />of repose of 38 degrees under low confining pressures. The low bound is considered <br />conservative when compared to the test results. <br />■ Clay. A consolidated - undrained (CU) triaxial test with pore pressure measurement was <br />performed on a sample of valley clay soil from the Collom Temporary Spoil Fill area <br />(Figure 11). In our opinion, this test result represents the best estimate of long term <br />drained strength for typical clayey soils expected below the South Taylor fills. This <br />effective stress shear strength of 31 degrees friction and no cohesion was used as the base <br />case. <br />We also considered a lower bound shear strength of 23 degrees, cohesion of 370 psf <br />(Figure 12) based on the results of five direct shear laboratory test results. In our opinion, <br />this value represents a reasonable lower bound for the clayey sand (SC) and low plasticity <br />sandy clay (CL) soil types found in the South Taylor area. <br />Rock. A rock mass shear strength estimate of 30 degrees friction and 5,220 psf cohesion <br />was used. The rock bedding in this area is favorable in that the bedding dip is into the <br />rock face towards the spoil fill. The shear strength is based on back - calculation of rock <br />slopes that were analyzed in the Collom area as described in our Feasibility Level <br />Geotechnical Study that analyzed the South Taylor Pit Slopes (Shannon & Wilson, <br />2006a). This shear strength estimate is intermediate between favorable dipping rock (10 <br />percent into the slope) and adverse dipping rock (10 percent out of the slope). This is a <br />conservative assumption as the rock bedding has a slightly favorable dip at about 7 <br />percent. <br />■ Groundwater. The permanent excess fill underdrains extend under this fill (Figure 1). <br />Our experience indicates that the base of the fill will consist of larger rock particles due <br />to sorting that occurs as the fill is end dumped in approximate 50- foot -tall lifts. This <br />sorting results in the base of the fill being relatively permeable. Considering these two <br />factors, significant water buildup in the base of the fill is not anticipated. . <br />23 -1 -01105 -600 <br />