Laserfiche WebLink
Analytical daufzlt reenanalytical.com p: 970247.4220 f: 970.2474227 75 Suttle Street Durango, CO 81303 <br />Laboratories <br />www.GreenAnalyticaLcom <br />XC Energy, LLC Project: Quarterly <br />5473 CR 120 Project Name / Number: King I and King II Reported: <br />Hesperus CO, 81326 Project Manager: Tom Bird 10/04/13 15:27 <br />Hay Gulch Ditch <br />King II <br />1309220 -03 (Water) <br />Analyte Result RL MDL Units Dilution Analyzed Method Notes Anahst <br />General Chemistry <br />Alkalinity, Bicarbonate* <br />101 <br />10.0 <br />mg/L <br />1 <br />09/30/13 <br />2320 B <br />ABP <br />Alkalinity, Carbonate* <br /><10.0 <br />10.0 <br />mg/L <br />1 <br />09/30/13 <br />2320 B <br />ABP <br />Alkalinity, Hydroxide* <br /><10.0 <br />10.0 <br />mg/L <br />1 <br />09/30/13 <br />2320 B <br />ABP <br />Alkalinity, Total* <br />101 <br />10.0 <br />mg/L <br />1 <br />09/30/13 <br />2320 B <br />ABP <br />pH* <br />8.18 <br />pH Units <br />1 <br />09/26/13 <br />EPA 150.1 <br />MJV <br />Sulfate <br />40.0 <br />10.0 <br />1.08 <br />mg/L <br />1 <br />09/27/13 <br />4500 -SO42- E <br />ABP <br />TDS* <br />165 <br />10.0 <br />mg/L <br />1 <br />10/01/13 <br />EPA 160.1 <br />JAW <br />Dissolved Metals by ICP <br />Calcium* <br />37.0 <br />1.00 <br />0.004 <br />mg/L <br />1 <br />10/01/13 <br />EPA200.7 <br />JGS <br />Hardness <br />139 <br />6.62 <br />0.088 <br />mgCaC031L <br />1 <br />10/01/13 <br />2340 B <br />JGS <br />Iron* <br /><0.050 <br />0.050 <br />0.004 <br />mg/L <br />l <br />10/01/13 <br />EPA200.7 <br />JGS <br />Magnesium* <br />11.2 <br />1.00 <br />0.019 <br />mg/L <br />1 <br />10/01/13 <br />EPA200.7 <br />JGS <br />Manganese* <br />0.008 <br />0.005 <br />0.0004 <br />mg/L <br />1 <br />10/01/13 <br />EPA200.7 <br />JGS <br />Sodium* <br />4.21 <br />1.00 <br />0.004 <br />mg/L <br />1 <br />10 /01/13 <br />EPA200.7 <br />JGS <br />Green Analytical Laboratories <br />Debbie Zufelt, Reports Manager <br />The results in this report apply to the samples analyzed in accordance with the chain of <br />custody document. This analytical report must be reproduced in its entirety. In no event <br />shall Green Analytical Laboratories be liable for incidental or consequential damages. <br />GALs liability, and clients "elusive remedy for any claim arising, shall be limited to the <br />amount paid by client for analyses. All claims, including those for negligence and any other <br />cause whatsoever, shall be deemed waived unless made in writing and received within <br />thirty days after completion of the applicable service. <br />Page 5 Of] 2 <br />