,jtoner Engineering & Surveying <br />Engineering, Testing & Surveying <br />The second location is along the east cut face of the old mine area along the road. The existing <br />berm utilized to redirect offsite flows around the east side of the site had washed out (see Pic. <br />2). The offsite flows then ran through the site and were collected into the existing water quality <br />features (see Pic. 3). The berming should be replaced to minimize the runoff routed through <br />the water quality ponds. This will reduce the overall ongoing maintenance costs for these <br />features as well as to prevent the ponds from being inundated with runoff that was not <br />intended to be captured which could result in overtopping of the structures. <br />The north runoff /drain filter located along the main drive experienced some bypass flows <br />during the latest storm events. The flows eroded the north side of the structure and resulted in <br />some limited erosion (see Pic. 4). The embankment material around the structure needs to be <br />replaced and any soil washed from the existing roadway embankment should be collected and <br />replaced. The collected sediment in both the north and south structures should be removed. <br />Please let me know if you have any additional questions or concerns in regards to the issues <br />that are discussed above or if the actual conditions differ from what I have stated above. <br />Sincerely, <br />` /ONAA <br />P.O. Box 1163 28 South Washington Street Cortez, Colorado 81321 <br />970.565.7483 stonerengineer @frontier.net 970.565.7704 <br />Ran M. Gri lak P.E. <br />Y g <br />Project Manager <br />cc <br />�� 43255 <br />m <br />` /ONAA <br />P.O. Box 1163 28 South Washington Street Cortez, Colorado 81321 <br />970.565.7483 stonerengineer @frontier.net 970.565.7704 <br />