Laserfiche WebLink
SEDCAD+ CULVERT SIZING UTILITY <br />• <br />CULVERT HRC-F4 <br />Design Discharge = 78.420 cfs <br />Entrance Loss Coefficient = 0.9 <br />Pipe Length = 100.000 feet <br />Pipe Slope = 2.000 6 <br />Meaning's n = 0.024 <br />Maximum Headwater = 4.620 feet <br />Tailwater Depth = 0.100 feet <br />Smallest Diameter Required to Pass Flow is 48 inches <br />CURVES: <br />Diameter: 42 inches <br /> <br /> <br />Headwater Discharge <br />(ft) (cfs) Control <br />Flow <br />Type <br />0.46 2.32 Inlet (Supercritical) 3 <br />0.92 6.52 Inlet (Supercritical) 3 <br />1.39 11.96 Inlet (Supercritical) 3 <br />1.85 18.41 Inlet (Supercritical) 3 <br />2.31 25.73 Inlet (Supercritical) 3 <br />2.77 33.82 Inlet (Supercritical) 3 <br />3.23 42.62 Inlet (Supercritical) 3 <br />3.70 52.08 Inlet (Supercritical) 3 <br />4.16 61.70 Inlet (Supercritical) 4 <br />4.62 69.37 Inlet 5 <br />5.08 76.62 Inlet 5 <br />5.54 83.19 Inlet 5 <br />6.01 87.58 Outlet 6 <br />6.47 91.51 Outlet 6 <br />6.93 95.29 Outlet 6 <br /> Diameter: 45 inches <br />Headwater Discharge Flow <br />(ft) <br />------------- (cfs) <br />------------ Control <br />------------------------ Type <br />--------- <br />0.46 2.48 Inlet (Supercritical) 3 <br />0.92 6.97 Inlet (Supercritical) 3 <br />1.39 12.81 Inlet (Supercritical) 3 <br />1.85 19.73 Inlet (Supercritical) 3 <br />2.31 27.57 Inlet (Supercritical) 3 <br />2.77 36.24 Inlet (Supercritical) 3 <br />3.23 45.67 Inlet (Supercritical) 3 <br />3.70 55.79 Inlet (Supercritical) 3 <br />4.16 66.57 Inlet (Supercritical) 3 <br />4.62 76.14 Inlet 5 <br />5.08 84.81 Inlet 5 <br />5.54 92.67 Inlet 5 <br />6.01 99.91 Inlet 5 <br />6.47 105.41 Outlet 6 <br />6.93 109.92 Outlet 6