My WebLink
|
Help
|
About
|
Sign Out
Search
SPDSS_Task7-2_WellUseWellAugmentationPlans
CWCB
>
Decision Support Systems
>
DayForward
>
SPDSS_Task7-2_WellUseWellAugmentationPlans
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2013 9:38:15 AM
Creation date
6/11/2008 2:31:12 PM
Metadata
Fields
Template:
Decision Support Systems
Title
SPDSS Task 7.2 - Well Use and Well Augmentation Plans
Description
This memorandum and associated appendices characterizes the 20 largest well augmentation plans and develops recommendations for representing well use and augmentation in SPDSS modeling efforts.
Decision Support - Doc Type
Task Memorandum
Date
12/14/2007
DSS Category
Groundwater
DSS
South Platte
Basin
South Platte
Contract/PO #
C153953
Grant Type
Non-Reimbursable
Bill Number
SB01-157, HB02-1152, SB03-110, HB04-1221, SB05-084, HB06-1313, SB07-122
Prepared By
Leonard Rice Engineering
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
APPENDIX A-7 Lower Platte & Beaver Canal Augmentation Plan -Plan ID 0102535 <br />The Lower Platte & Beaver Canal Company (Lower Platte & Beaver Co.) is a mutual ditch <br />company in Morgan County on the south side of the South Platte River in Water District 1 (see <br />Figure 1). The Lower Platte & Beaver Co. Augmentation Plan decree (Case No. W-2969) <br />consists of 101 wells, a 1972 priority direct flow water right and 10 recharge facilities, including <br />the ditch itself, within the Lower Platte & Beaver Co. service area. Additional recharge sites and <br />augmentation wells as a direct augmentation supply are included as part of Lower Platte & <br />Beaver Company's pending Water Court application (Case No. 03CW443) to amend its existing <br />augmentation plan. <br />The number of wells associated with the augmentation plan from sources reviewed for this effort <br />is summarized in Table 1. <br />Table 1 <br />Wells Associated with Lower Platte & Beaver Au mentation Plan Plan ID 0102535 <br />Source Number of Wells <br />W-2969 decree 101 <br />H droBase association (Version 20060816) 105 <br />Tied to acrea e in GIS Irri ated Acrea e Assessment* 95 <br />User interview 101 <br />* Subset of HydroBase association using wells decreed for irrigation with decreed rates greater than 50 gpm and specifically tied <br />to lands in the 2001 Irrigated Acreage Assessment. <br />A number of possible explanations exist for the variation in number of wells listed in the decree <br />versus HydroBase, including: <br />• Some augmentation plan decrees allow wells to be added to the plan without re-adjudicating <br />the plan. <br />• Some wells listed in HydroBase may be recharge wells, augmentation wells, or decreed for <br />other uses. <br />• Some wells may have been replaced and the original wells are still included in HydroBase. <br />A number of possible explanations exist for the variation in number of wells tied to acreage from <br />the list of wells in HydroBase, including: <br />• Wells may be mis-located in the GIS coverage and therefore not assigned to irrigated <br />parcel(s). <br />• Wells are not active. <br />• Wells not decreed or decreed for less than 50 gallons per minute. <br />• Wells are decreed for other uses (e.g., augmentation, recharge, domestic, municipal, <br />commercial, stock water, etc.). <br />• The association of a well to the augmentation plan ID may be incorrect in HydroBase. <br />System Overview <br />The Lower Platte & Beaver Co. Augmentation Plan is used to divert the 1972 junior direct flow <br />recharge right, in priority, into various recharge sites under the ditch system when water is <br />available in the South Platte River. The ditch company prefers to run recharge water when there <br />is no irrigation water carried through the system because they receive recharge credit for the <br />A-39 ofA-106 <br />
The URL can be used to link to this page
Your browser does not support the video tag.