My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WSP07725
CWCB
>
Water Supply Protection
>
Backfile
>
7001-8000
>
WSP07725
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2010 2:28:41 PM
Creation date
10/12/2006 2:33:30 AM
Metadata
Fields
Template:
Water Supply Protection
File Number
8146.100
Description
Pueblo Dam - Project Description
State
CO
Basin
Arkansas
Water Division
2
Date
1/1/3000
Author
US DoI BoR
Title
Drawings - Initial Construction fro Pueblo Dam - Specifications No DC-6820 Volume 2 of 2 Drawings No 121 to 380 Inclusive
Water Supply Pro - Doc Type
Data
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br />Par. 152 <br /> <br />.0694 <br /> <br />374. Ap.3001-Sheat lOf 4. <br />375. AP.3001-Sheat 2 Of 4. <br />376. Ap.3001-Sheet 3 Of 4. <br />377. AP-3001-Sheet 4 Of 4, <br />378. AP-3002. <br />379. AP.3059 Through Ap.3070 (no detailed <br />lOB)-Pagel Of 2. <br />380. AP.3079 Through AP-3070 (no detailed <br />IOB)-Page 2 Of 2. <br /> <br />b. Generel.-Some of the drawings are typeical <br />designs only and the dimensions of each structure <br />will be fixed by the contracting officer to adapt tha <br />structure to the existing conditions at the structura <br />location. Where details shown on tha 40.0- and <br />4Q.C. series standard drawings differ from those <br />shown on other drawings ortha requirements of <br />these specifications, tha details shown on the other <br />drawings or required by the specifications shall <br />govern. The contractor shailcheck all drawings <br />carefully and shall advise the contracting officer of <br />any errors or omissions discovered. <br /> <br />Except as otherwise provided in these specifications <br />for drawings to be furnished by the contractor, <br />additional detail drawings will ba furnished to the <br />contractor for construction purposes, where <br />nec....ry, as determined by the contracting officer. <br /> <br />Some of the drawings included herein show details <br />of fabrication, and other details and specifications <br />not a part of work required under these <br />specifications. Specifications and details shown on <br />these drawings which are not applicable under these <br />specifications shall be disregarded. Reference <br />drawings referred to on enclosed drawings, and not <br />Included herein, are not considered necessary ,for <br />bidding purposes but will be furnished to ~he <br />contractor, where necessary, for ccinstructlon <br />purposes, Where details shown on Standard <br />Drawings (4Q.D. and 40.C. series) differ from those <br />shown on other drawings or the requirements of <br />these specifications, the details shown on other <br />drawings or the requirements of the specifications <br />shall govern. In the event there are minor <br />differences as determined by the contrecting officer <br />betwean details end dimensions shown on the <br />drawings and those of existing feetures at the site, <br />the details and dimensions of existing features at the <br />site shall govern. <br /> <br />Drawings of the existing Rock Canyon Barrier Dam <br />are included for the information of bidders. The <br />conversion of the datum used in the rock canyon <br />Barrier Dam drawings to the U.S. Coast and <br /> <br />:) '., . ' <br />,.", '.J <br />> ,-,' ~'. \. <br /> <br />Geodetic Survey datum uSed in the specification <br />drawings can be made by subtrectlng 13.3 feet from <br />the elevations shown on the Rock Canyon Barrier <br />Dam drawings. <br /> <br />. <br /> <br />The enclosed drawings wiil be supplemented by <br />such additional or revised genaral and datail <br />clrawlngs as may be necessary or desirable as tha <br />Work progresses; and the contractor shail do no <br />Work without proper drawings and Instructions, The <br />~ddltlonal or revised general and detail drawings <br />furnished by the Government wlli'show dimensions <br />and details neces.Sary for construction purposes <br />more completaly than. are shown on'the enclosed <br />drawings for all. features of the work. The <br />contractor will be required to perform the work in <br />accordance with the additional general and detail <br />l\rawings or revisions furnished by the Government <br />at the applicable prices bid in the schedule for such <br />work. . <br /> <br />,1 <br /> <br />. <br /> <br />The contractor shall check all drawings carefully <br />a.nd advise the contrecting officer of any errors or <br />omissions discovered, <br /> <br />The contractor wiil be furnished such additional <br />copies of the specifications and drawings as may be <br />r~ulred for carrying out the work. Full-1;ize contact <br />prints of the. original drawings from which the <br />attached reproductions were made, other than 40.0- <br />and40.C. series standard drawings will be furnished <br />to the contractor for construction purposes upon <br />request. Additional roto prints of the. 4Q.D- and <br />4Q.C. drawings will ba furnished upon request. The <br />number of prints of each drawing furnished to the <br />cpntractor will be limited to 10 contact prints and 1 <br />reproducible. . <br /> <br />. <br /> <br />All drawings and deta submitted by the ContraCtor <br />f6r which a specific mailing address is not given in <br />these specifications shail be subm.itted to <br />Construction Enginear, Post Office Box 551, Salida, <br />Colorado 81201. <br /> <br />. <br /> <br />. <br /> <br />. <br /> <br />Interior-Reclamation, Denver, Colorado <br />vi <br />
The URL can be used to link to this page
Your browser does not support the video tag.