Laserfiche WebLink
<br />Response: <br /> <br />The text has been changed to read, "14,050 to 16,000 feet." <br /> <br />76. Ccmrent: <br /> <br />Page 18, first full paragraph: If it is known, as stated, that the host <br />formations have sufficient hydraulic characteristics to accept the injected <br />br ines, why the two year test per iod? <br /> <br />Response: <br /> <br />The text has been changed to read, "are expected to <br />permea bili ty and porosi ty. " The two-year test <br />determine the validity of this assumption. <br /> <br />have sufficient <br />period would help <br /> <br />77 . Ccmrent: <br /> <br />Page 18, second paragraph, second sentence: <br />within the disposal horizon during the <br />canpletion? <br /> <br />will the injected brine remain <br />test period as well as after <br /> <br />Response: <br /> <br />As stated in the text the injected brine would remain with the disposal zone <br />during testing and operation. <br /> <br />78. Ccmrent: <br /> <br />Page 19, <br />4). The <br />reduction <br /> <br />under Hydrology: The current brine inflow is 205,000 tons (page <br />second sentence should read "...25 to 50 percent of the proposed <br />is brine inflow. <br /> <br />Response: <br /> <br />The text has been changed to clarify the quantity of brine inflow. <br /> <br />79. Ccmrent: <br /> <br />Page 20, Endangered Species: Need to explain the need for reinitiation of <br />Section 7 consultation upon canpletion of the testing. <br /> <br />Response: <br /> <br />The text on endangered species has been changed. <br /> <br />nn (183 <br />.: \J <br /> <br />47 <br />