My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WSPC05649
CWCB
>
Water Supply Protection
>
Backfile
>
17000-17999
>
WSPC05649
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2010 12:02:15 PM
Creation date
10/9/2006 5:25:02 AM
Metadata
Fields
Template:
Water Supply Protection
File Number
8062
Description
Federal Water Rights - Colorado Litigation - National Forest ISF Claims - Technical Sutdies
State
CO
Basin
Statewide
Date
9/10/1985
Author
Unknown
Title
Technical Studies - Water Information Management System Handbook
Water Supply Pro - Doc Type
Report/Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />0017112 <br /> <br />36.2--7 <br /> <br />WATER INFORMATION MANAGEMENT SYSTEM HANDBOOK <br /> <br />( <br /> <br />(6) column 5 is not applicable. <br /> <br />(7) Record the QLl IQB ratio value in column 6. <br /> <br />(8) Multiply the QLI/QB ratio value by Qa to calculate CFS flow <br />for QLl and record In column 7. <br /> <br />(9) Calculate a time-volume coefficient for QLl' The total days in <br />the baseflow-duration period (in this example, 283 days) is multiplied by <br />the QLI/QB ratio value and by 1.9835. Record this value in column 8. <br /> <br />(10) Calculate the total AcFt for the baseflow period. Multiply the <br />TVC by QB (in CFS) and record In column 9. <br /> <br />e. QL2 baseflow (row labeled QL2 in ex. 3): <br /> <br />The QL2 baseflow component is calculated to provide an estimate of the <br />volume of natural flows less than QLl' The QL2 baseflow duration is <br />the remainin9 amount of time from.the end of QLl on the flow-duration <br />curVe percent time scale (In this example 91.56 to 100.06 or 8.56); <br /> <br />(1) Read the percent time limits from the flow-duration curve and <br />record in column 1. <br /> <br />(2) Calculate the percent time increment and record in column 2. <br /> <br />(3) Multiply the percent time increment by 365 days (for the number <br />of days in the QL2 baseflow component) and record in column 3. <br /> <br />(4) Round to the nearest whole day the days increment and record in <br />column 4. <br /> <br />(5) Column 5 is not applicable. <br /> <br />(6) Read the median percent time pOint between the beginning of the <br />QL2 component (that is, 91.5) and the end of the time scale (for <br />example, 99.99) from the flow-duratlon curve. This Q/QB ratio value <br />represents the average flow rate for QL2. Record this ratio value in <br />col umn 6. <br /> <br />(7) Multiply the ratio value in column 6 by.QB to produce a CFS <br />flow rate for QL2 and record in column 7. <br /> <br />(8) Calculate a.time-volume coefficient for QL2 by multiplying the <br />number of days duratIon in the time increment (column 4) by the ratio <br />value (column 6) and by 1.9835. Record the result in column 8. <br /> <br />i, <br /> <br />10 No. 1 <br />9/1 0/8 S <br />
The URL can be used to link to this page
Your browser does not support the video tag.