Laserfiche WebLink
<br />- <br /> <br />STATWJF COLORADO <br /> <br />o <br /> <br />.' <br />, <br />~..~ -.. .. <br /> <br />. <br /> <br />Colorado Water Conservation Board <br />Department of Natural Resources <br />721 Sl2Ie Cp",,,,,m.l Building <br />i313 Sh= Street <br />Denver, eo1=do 80203 <br />Phone (303) 866-3441 <br />FAX (303)86&4474 <br /> <br />MEMORANDUM <br /> <br />Roy Romer <br />Govemor <br /> <br />James 5.1.....""'" <br />fu=ltive DiI<:aor. DNR <br /> <br />Danes C. Lile. P.E. <br />Di=lor. CWCB <br /> <br />(upDATED March 27, 1996) <br /> <br />TO: Colorado Water Conservation Board Members <br /> <br />FROM: John Van Sciver <br /> <br />DATE: March 4, 1996 <br /> <br />SUBJECT: Agenda Item 4d., March 12-13-14, 1996, Board~Meeting-- <br />Tremont Mutual Ditch Company <br />Approval of a Small Project Construction Fund Loan in amount of $27,000 <br />to rehabilitate the Company's Diversion Structure on the South Platte River. <br /> <br />BACKGROUND <br /> <br />. <br /> <br />The Tremont Mutual Ditch Company (located in Morgan County), has submitted an application <br />for a loan to rehabilitate their west headgate structure, at their South Platte diversion, They are <br />requesting a loan in the amount of $27K (75% of the estimated total project cost of $36K), <br /> <br />The purpose of the project is to rebuild one of the Company's existing headgates, about 6 miles <br />east of Fort Morgan, The west headgate was rebuilt after the 1965 flood, and was totally <br />destroyed during spring runoff flooding in 1995, The river flooded to the north, and cut a new <br />channel around the diversion dam across the river (owned by the Lower Platte and Beaver,) <br />Tremont uses this diversion dam, under contract with Lower Platte and Beaver, Although the <br />diversion dam was not damaged, the Tremont west headgate was washed out, <br /> <br />The west headgate can not be used until repairs are made, Operation with just the east headgate <br />would cause sand to plug the ditch, and render it inoperable in a short time, <br /> <br />Preliminary engineering design work as well as a draft feasibility study have been completed by <br />Bart Woodard and Cecil Osborne, P,E, <br /> <br />DISCUSSION <br /> <br />. <br /> <br />The proposed project will maintain the current capacity of 70 CFS, with an ability to supply <br />about 140acre feet of water per day during irrigation season, The Company actually diverted <br />2410,75 acre feet through the structure in 1994, according to S,E,O records, About 2000 acres <br />are irrigated by the Tremont Ditch, <br />