Laserfiche WebLink
<br />HEC-l INPUT DESCRIPTION <br />DIVERSION DATA (0 Cards) <br /> <br />7.3 DO CARD - DIVERSION OPTIMIZATION <br /> <br />Data required for optimization of diversion capacity are: <br /> <br />Diversion Identification <br />Diverted Flow vs. Inflow <br />Cost vs. Capacity <br />Cost Factors, Range <br /> <br />. <br /> <br />FIELD VARIABLE <br /> <br />VALUE <br /> <br />Col 1+2 ID <br /> <br />DO <br /> <br />1 IOPTD <br /> <br />+ <br /> <br />0, or <br />Blank <br /> <br />2 <br /> <br />DANCST <br /> <br />+ <br /> <br />---- <br /> <br />3 <br /> <br />DOSCNT <br /> <br />+ <br /> <br />4 <br /> <br />DVRMX <br /> <br />+ <br /> <br />5 <br /> <br />DVRMN <br /> <br />+ <br /> <br />, <br /> <br />.; <br /> <br />DT card <br />01, DQ cards <br />DC, DO cards <br />DO card <br /> <br />DESCRIPTION <br /> <br />Card identification. <br /> <br />Number of field on OS card which contains <br />capacity of diversion. <br /> <br />Diversion capacity is not optimized. <br /> <br />Proportion of capital cost of diversion <br />that will be required for annual operation <br />and maintenance. <br /> <br />Discount <br />compute <br />cost. <br /> <br />factor (capital recovery factor) to <br />equivalent annual cost from capital <br /> <br />Maximum permissible capacity of diversion in <br />cfs (cu .m/sec). Used as a constraint on optimization. <br /> <br />Minimum permissible capacity of diversion <br />cfs (cu mfsec). Used as a constraint on <br />optimization. <br /> <br />Page 27 <br />